适应性[公式:参见文本] 过器设计用于网络控制系统的通信阻塞网络攻击
Muhammad Ali1, Ghulam Mustafa1, Hasnain Ahmad1
1Department of Electrical Engineering, Pakistan Institute of Engineering and Applied Sciences (PIEAS), Islamabad, Pakistan.
Scientific reports
|July 30, 2025
概括
这项研究引入了一种新的过器设计,用于面临通信干扰的网络系统. 过器确保了系统的稳定性和性能,而不需要知道干扰器何时激活,提高了80%以上的准确性.
科学领域:
- 控制系统工程 控制系统工程
- 网络系统安全 网络系统安全
- 信号处理 信号处理
背景情况:
- 通信干扰会在联网系统中造成不可预测的延迟,使过器设计复杂化.
- 现有的过方法在因干扰攻击而导致的时间变化的传输间隔方面扎.
研究的目的:
- 开发一个强大的过器,用于在隐蔽通信干扰下网络采样数据系统.
- 为了保证无边形稳定性和H-infinity性能,尽管干扰.
主要方法:
- 利用一个多重点框架来模拟被干扰引入的不确定性.
- 公式分析和合成条件作为线性矩阵不等式,用于全序H无限度过器.
- 开发了一种不需要对干扰器活动事先了解的过器设计.
主要成果:
- 拟议的过器保证了在隐蔽干扰下对异位稳定性和H无限性性能.
- 与现有方法相比,H-infinity性能得到了80%以上的改进.
- 过器的精度可以通过调整多类型模型复杂度来调整.
结论:
- 拟议的H-infinity过器有效地减轻了网络采样数据系统中的隐形通信干扰.
- 离线设计和增强的性能使其适用于资源有限的嵌入式控制系统.
- 这种方法为在对抗性网络环境中进行强大的过提供了一个新的解决方案.
相关概念视频
Feedback control systems
429
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
429
Design Example
372
The innovation of touch-tone telephony revolutionized the telecommunications industry by replacing the traditional rotary dial with a dual-tone multi-frequency (DTMF) signaling system. This system uses a matrix-style keypad with buttons arranged in four rows and three columns, creating 12 distinct signals each assigned to a pair of frequencies. Each button press results in a simultaneous generation of two sinusoidal tones – one from a low-frequency group (697 to 941 Hz) and one from a...
372
Line Protection with Impedance Relays
135
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
135
Control Systems
1.4K
Control systems are everywhere in contemporary society, influencing diverse applications from aerospace to automated manufacturing. These systems can be found naturally within biological processes, such as blood sugar regulation and heart rate adjustment in response to stress, as well as in man-made systems like elevators and automated vehicles. A control system is essentially a network of subsystems and processes that collaboratively convert specific inputs into desired outputs.
At the heart...
At the heart...
1.4K
Radial System Protection
149
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
149
Network Function of a Circuit
391
Frequency response analysis in electrical circuits provides vital insights into a circuit's behavior as the frequency of the input signal changes. The transfer function, a mathematical tool, is instrumental in understanding this behavior. It defines the relationship between phasor output and input and comes in four types: voltage gain, current gain, transfer impedance, and transfer admittance. The critical components of the transfer function are the poles and zeros.
391