降级前便于降级前剖析和重新进入:跨越无线的新解决方案将会随之而来
1Division of Cardiology, Banner University Medical Center, Phoenix, Arizona, USA.
JACC. Case reports
|August 1, 2025
概括
穿皮冠状动脉干预 (PCI) 中气球不可穿越的病变是一个挑战. 在这些困难的PCI病例中,Stingray导管提供了一种新的解决方案,用于降级前解剖和重新进入.
科学领域:
- 干预心脏病学 干预心脏病学
- 血管外科 血管外科
背景情况:
- 慢性全闭塞 (CTO) 的穿皮冠状动脉干预 (PCI) 经常面临着无法穿过气球的病变的挑战.
- 这些病变的特点是,在导线穿过后不能与气球或微导管穿过,在复杂的非CTO病例中也会出现化和曲的情况.
更多相关视频
相关概念视频
Cable: Problem Solving
868
When dealing with a cable that is fixed to two supports and subjected to uniform loading, it is crucial to determine the maximum tension in the cable. This process can be broken down into several key steps, as outlined below:
868
Interference: Path Lengths
2.5K
Consider two sources of sound, that may or may not be in phase, emitting waves at a single frequency, and consider the frequencies to be the same.
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
2.5K
Reducing Line Loss
524
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
524
Transport Number
230
The transport number is the fraction of the total current carried by an ion in an electrolyte solution. It is defined as the ratio of the current carried by a specific ion to the total current flowing through the solution. The transport number, t, is central to understanding ionic mobility, which describes how fast an ion moves under the influence of an electric field. This link connects the physical behavior of ions in solution to the chemical processes that occur during electrochemical...
230
Fast Decoupled and DC Powerflow
961
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
961
Boundary Conditions: Lossless Lines
482
Consider a single-phase, two-wire, lossless transmission line terminated by an impedance at the receiving end and a source with Thevenin voltage and impedance at the sending end. The line, with length, has a surge impedance and wave velocity determined by the line's inductance and capacitance.
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
At the receiving end, the boundary condition states that the voltage equals the product of the receiving-end impedance and current. This relationship is expressed as a function of the incident and...
482


