使用电阻和弹性波速来估计部分和沙 - 黑马混合物的综合孔隙性
Jong-Sub Lee1, Hyun Seok Kang1, Dongsoo Lee1
1School of Civil, Environmental and Architectural Engineering, Korea University, 145, Anam-ro, Seongbuk-gu, Seoul, 02841, Republic of Korea.
Scientific reports
|August 7, 2025
概括
评估矿山尾矿的多孔性对于大安全至关重要. 电电阻比弹性波更可靠,用于评估沙子 - 黑马混合物,有助于地质技术监测.
科学领域:
- 地质技术工程 地质技术工程
- 地质物理学 地质物理学
- 环境科学 环境科学
背景情况:
- 矿山尾矿的有效维护和故障预防需要在和和部分和条件下精确的孔隙性评估.
- 了解尾矿材料的特性对于可持续的资源管理和地质技术监测至关重要.
研究的目的:
- 为了评估不同含量和和度的白血混合物的多孔性.
- 为了比较电阻力和弹性波速的有效性,作为在尾矿材料中测定孔隙性的地质物理方法.
主要方法:
- 实验调查使用一个专门设计的电池与曲元件,压力磁盘元件,电阻探测器和时间域反射计探测器.
- 系统地改变血含量 (重量为0-30%) 并控制水位的调节,以模拟不同的和条件.
- 对介电常数,电电阻和弹性波速变化的分析,以应对变化的和和血含量.
主要成果:
- 随着水位的变化,观察到介电常数和电电阻的显著变化.
- 弹性波速受到特定水位上的血含量和毛细血管效应的影响.
- 基于电阻的方法在孔隙性评估中显示出更高的可靠性,而不是基于错误规范分析的基于弹性波的方法.
结论:
- 综合实验框架提供了一种有效的方法来评估尾材料的多孔性.
- 电阻是一种比弹性波速更可靠的地理物理方法来评估这些材料的孔隙性.
- 这项研究有助于改善地质技术监测和矿山尾矿的可持续管理.
更多相关视频
09:46Protocol for Measuring the Thermal Properties of a Supercooled Synthetic Sand-water-gas-methane Hydrate Sample
Published on: March 21, 2016
9.0K
07:21Author Spotlight: Advancing Agricultural Land Ecosystem Research with a Hydraulic Property Analyzer to Assess Soil Health
Published on: August 9, 2024
1.1K
相关概念视频
Porosity and Absorption of Aggregate
403
Aggregates contain pores of varying sizes; while some are completely enclosed within the particles, others open onto the surface, allowing water to penetrate. The porosity of aggregates is a major factor contributing to the overall porosity of concrete, given that aggregates constitute about three-quarters of concrete's volume.
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
When all pores in an aggregate are filled with water, the aggregate is considered saturated and surface-dry. If left in dry air, water will evaporate until the...
403
Porosity in Cement Paste
228
The porosity of concrete is a measure of the void spaces within its structure. These spaces impact its strength and durability significantly. When water and cement interact, a chemical reaction called hydration creates a semi-solid paste. This paste includes combined water, making up approximately 23% of the cement's dry mass, and gel water, which fills minuscule voids known as gel pores, accounting for about 28% of the cement gel volume.
The balance of water to cement in the mix is...
The balance of water to cement in the mix is...
228
Permeability of Concrete
214
Permeability in the context of concrete refers to how easily liquids or gases can pass through the material. This quality is crucial for assessing the water-tightness and durability of concrete structures and their resistance to chemical attacks. Concrete permeability can be determined through comparative laboratory tests. These tests typically involve sealing a concrete specimen from the sides, applying water pressure to the top surface with pressure, and measuring the amount of water passing...
214
Resistivity
3.6K
When a voltage is applied to a conductor, an electrical field is generated, and charges in the conductor feel the force due to the electrical field. The current density that results depends on the electrical field and the properties of the material. In some materials, including metals at a given temperature, the current density is approximately proportional to the electrical field. In these cases, the current density can be modeled as:
3.6K
Susceptibility, Permittivity and Dielectric Constant
1.8K
When placed in an external electric field, a dielectric material gets polarized. The charge density in the dielectric material is given by the sum of the bound and free charge densities, while the total charge density can also be written in terms of the total electric field. The bound charge density can be measured in terms of polarization, leading to the relationship between electric displacement and polarization.
1.8K
Magnetic Susceptibility and Permeability
1.4K
In linear magnetic materials, like paramagnets and diamagnets, magnetization is proportional to the magnetic field intensity. The constant of proportionality, a dimensionless number, is called magnetic susceptibility. The value of the susceptibility depends on the type of material.
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
When diamagnetic materials are placed under an external magnetic field, the moments opposite to the field are induced. Hence, the susceptibility for diamagnets has a minimal negative value of 10-5–10-6. Since...
1.4K