Michaela Bocheva1, Dobromir Rahnev2

  • 1Department of Psychology, Yale University, 100 College Street, New Haven, CT, 06510, USA. michaela.bocheva@yale.edu.

PubMed
概括

在决策任务中切换运动反应会削弱信心泄漏,这是过去的信心影响当前判断的现象. 这表明运动流性会影响元认知评估.

相关概念视频

Confidence Coefficient01:24

Confidence Coefficient

The confidence coefficient is also known as the confidence level or degree of confidence. It is the percent expression for the probability, 1-α, that the confidence interval contains the true population parameter assuming that the confidence interval is obtained after sufficient unbiased sampling; for example, if the CL = 90%, then in 90 out of 100 samples the interval estimate will enclose the true population parameter. Here α is the area under the curve, distributed equally under...
7.9K
Hierarchy of Motor Control01:18

Hierarchy of Motor Control

The hierarchy of motor control refers to the different levels of organization and processing involved in controlling movement in the body. These levels range from higher cortical areas involved in planning and decision-making to lower spinal cord reflexes that respond automatically to external stimuli.
3.6K
Electro-mechanical Systems01:19

Electro-mechanical Systems

Electromechanical systems are intricate configurations that effectively combine electrical and mechanical elements to achieve a desired outcome. Central to many of these systems is the DC motor, a device that converts electrical energy into mechanical motion, enabling various applications ranging from simple fans to complex robotic mechanisms.
A key component of the DC motor is the armature, a rotating circuit positioned within a magnetic field. As an electric current passes through the...
1.2K
Time-Domain Interpretation of PD Control01:07

Time-Domain Interpretation of PD Control

Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
178
Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state...
276
Motor Unit Stimulation01:20

Motor Unit Stimulation

When the neuron of a motor unit fires an action potential, it triggers a series of events, leading to a twitch contraction in the muscle fibers. The process of excitation-contraction coupling is crucial in relaying the action potential to the muscle fibers.
The latent period of contraction marks the onset of excitation-contraction coupling, when the action potential propagates across the sarcolemma, preparing the muscle fibers for contraction. As the fibers enter the contraction phase, the...
2.0K