低噪音光学光谱仪具有高光谱范围与分辨率比率
概括
一个新的光学衍射格子光谱仪可以实现高光谱分辨率,而不需要移动的部件. 这种紧,高效的设备是便携式微量气体传感应用的理想选择.
科学领域:
- 频谱学是一种光谱学.
- 光学工程是指光学工程.
- 分析化学 分析化学
背景情况:
- 传统的光谱仪往往需要移动的部件,增加复杂性和限制便携性.
- 高分辨率光谱对于微量气体分析中的敏感检测至关重要.
研究的目的:
- 开发一个紧的,高分辨率的光学衍射格子光谱仪.
- 为了证明其适用于便携式微量气体传感应用的适用性.
主要方法:
- 使用光学衍射格式光谱仪设计.
- 包含一个快速的F0.95/50毫米相机镜头.
- 在没有机械元件的情况下实现了光谱分散.
主要成果:
- 在3800厘米-1的范围内达到1.4厘米-1的光谱分辨率.
- 证明了高检测效率 (>50%的p极化绿光).
- 在低噪音和没有热电冷却的情况下运行,体积小于2升.
结论:
- 开发的光谱仪在一个紧的,坚固的设计中提供了高性能.
- 它的功能非常适合要求高的便携式光谱任务.
- 能够进行高分辨率,低光谱测量,用于微量气体的探测.
相关概念视频
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
296
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
296
UV–Vis Spectrometers
1.5K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.5K
Raman Spectroscopy Instrumentation: Overview
532
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
532
IR Spectrometers
1.5K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.5K
Super-resolution Fluorescence Microscopy
7.6K
Super-resolution fluorescence microscopy (SRFM) provides a better resolution than conventional fluorescence microscopy by reducing the point spread function (PSF). PSF is the light intensity distribution from a point that causes it to appear blurred. Due to PSF, each fluorescing point appears bigger than its actual size, and it is the PSF interference of nearby fluorophores that causes the blurred image. Various approaches to achieving higher resolution through SRFM have recently been...
7.6K
NMR Spectrometers: Resolution and Error Correction
775
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...
775