概括
这项研究澄清了四流理论中的"扩散"术语,用于模拟光散射. 简单的校正在将模型与集成球体测量进行比较时提高了准确性.
科学领域:
- 光学和光子学 在光学和光子学.
- 材料科学 材料科学 材料科学
背景情况:
- 四流理论模型的光散射通过多层系统使用扩散和聚合性质.
- 使用集成球体或光度仪进行的实验测量通常近似分散光,无法将前向分散的聚合组件分开.
研究的目的:
- 为了澄清在各种散射环境中"扩散"光的定义.
- 在与实验数据相比时,提出简单的纠正来提高四流模型的准确性.
主要方法:
- 分析分散光散射和聚合光散射之间的区别.
- 基于样本雾和整合球体几何学的校正因子的开发.
主要成果:
- 在散射模型和测量中更清楚地了解散射光.
- 在将四流理论预测与实验结果进行比较时表现出更高的准确性.
结论:
- 将四流模型与实验数据进行准确的比较,需要仔细考虑分散光的定义.
- 建议的纠正提供了一种实际的方法来提高光散射模拟的准确性.
相关概念视频
Flame Photometry: Lab
362
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
362
Flame Photometry: Overview
804
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
804
Total Internal Reflection Fluorescence Microscopy
6.6K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
6.6K
Calculation of Electric Flux
2.2K
Consider the electric field of an oppositely charged, parallel-plate system and an imaginary box between those plates. Let the bottom face of the box be ABCD, and the top face be FGHK. The electric field between the plates is uniform and points from the positive plate toward the negative plate. The calculation of this field's flux through the box's various faces shows that the net flux through the box is zero. Why does the flux cancel out here?
2.2K
Fluorescence and Phosphorescence: Instrumentation
739
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
739


