相关实验视频
Updated: Sep 11, 2025

11:34
Scattering And Absorption of Light in Planetary Regoliths
Published on: July 1, 2019
10.4K
概括
这项研究展示了用于绘制对象极化性质的计算幽灵极度测量. 这种新的技术使用单臂设置在经典光线中重建相异形.
科学领域:
- 光学和光子学 在光学和光子学.
- 计算成像技术的成像
- 极极度度测试是指极极度测试的方法.
背景情况:
- 幽灵成像能够在单臂光学设置中检索对象信息.
- 极极度测量对于描述材料光学性质至关重要.
- 计算方法在光学测量方面提供了先进的解决方案.
研究的目的:
- 为了实验地实现经典光的计算幽灵极度测量.
- 为了证明对具有相异质的物体的极化属性地图的重建.
- 验证一种用于分析异性质材料的新方法.
主要方法:
- 使用计算幽灵成像原理.
- 在极化分析中应用斯矩阵形式主义.
- 开发一个单臂光学设置用于极度测量.
主要成果:
- 计算机幽灵极度测量的成功实验实施.
- 证明了极化特性地图的重建.
- 对表现相异质的物体的方法的验证.
结论:
- 计算幽灵极度测量是一种可行的技术,用于描述极化特性.
- 该方法允许在光学材料中详细地绘制相异性异性.
- 这种方法可以对具有空间变化的振幅和相异质的物体进行概括.
相关概念视频
Potential Due to a Polarized Object
471
A neutral atom consists of a positively charged nucleus surrounded by a negatively charged electron cloud. When placed in an external electric field, the external electric force pulls the electrons and nucleus apart, opposite to the intrinsic attraction between the nucleus and the electrons. The opposing forces balance each other with a slight shift between the center of masses of the nucleus and the electron cloud, resulting in a polarized atom. On the other hand, a few molecules, like water,...
471
Curvilinear Motion: Polar Coordinates
476
In polar coordinates, the motion of a particle follows a curvilinear path. The radial coordinate symbolized as 'r,' extends outward from a fixed origin to the particle, while the angular coordinate, 'θ,' measured in radians, represents the counterclockwise angle between a fixed reference line and the radial line connecting the origin to the particle.
The particle's location is described using a unit vector along the radial direction. Deriving the particle's position...
The particle's location is described using a unit vector along the radial direction. Deriving the particle's position...
476
¹³C NMR: Distortionless Enhancement by Polarization Transfer (DEPT)
1.2K
When proton-coupled carbon-13 spectra are simplified by a broadband proton decoupling technique, structural information about the coupled protons is lost. Distortionless enhancement by polarization transfer (DEPT) is a technique that provides information on the number of hydrogens attached to each carbon in a molecule. While the DEPT experiment utilizes complex pulse sequences, the pulse delay and flip angle are specifically manipulated. The resulting signals have different phases depending on...
1.2K
Group Polarization
35.5K
Group polarization is the strengthening of an original group attitude following the discussion of views within a group (Teger & Pruitt, 1967). That is, if a group initially favors a viewpoint, after discussion the group consensus is likely a stronger endorsement of the viewpoint. Conversely, if the group was initially opposed to a viewpoint, group discussion would likely lead to stronger opposition.
35.5K
Polar and Cylindrical Coordinates
15.6K
The Cartesian coordinate system is a very convenient tool to use when describing the displacements and velocities of objects and the forces acting on them. However, it becomes cumbersome when we need to describe the rotation of objects. So, when describing rotation, the polar coordinate system is generally used.
15.6K
Phase Contrast and Differential Interference Contrast Microscopy
9.5K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
9.5K

