对于TriOS RAMSES辐射传感器的沉浸系数确定
Optics express
|August 13, 2025
概括
确定了TriOS RAMSES辐射传感器的沉浸系数,显示传感器与先前研究之间的差异很小. 为RAMSES传感器类提出了一个一致的平均沉浸系数.
科学领域:
- 海洋光学 海洋光学
- 放射测量是一种放射测量.
- 传感器的校准 传感器的校准
背景情况:
- 精确的水中辐射测量对于海洋学研究至关重要.
- 沉浸因子对于纠正水生环境中的传感器读数至关重要.
- 之前的研究确定了RAMSES高光谱辐射计的沉浸系数.
研究的目的:
- 确定TriOS RAMSES ARC系列辐射传感器的沉浸系数.
- 将这些因素与同一类传感器的现有数据进行比较.
- 为RAMSES辐射传感器类提出一个代表性的沉浸系数.
主要方法:
- 采用Zibordi (2006) 的方法来确定沉浸因子.
- 使用了两个不同的光源:LED和-灯.
- 与Zibordi和Darecki (2006) 对RAMSES高光谱辐射计的结果进行比较.
主要成果:
- 两个测试的传感器的沉浸系数差异为0.2%.
- 确定的因素与Zibordi和Darecki (2006) 的平均差异为0.3%.
- 结果表明,RAMSES辐射传感器类的沉浸因子一致.
结论:
- 对于RAMSES辐射传感器的沉浸系数对于类表示是足够的常数.
- 建议从这项研究和先前的工作中得出的平均沉浸因子.
- 拟议的平均沉浸因子显示,从400nm到900nm的平方根平均差异小于0.2%.
相关概念视频
Impedance Combination
504
Consider a string of christmas lights, each bulb symbolizing an impedance element. In this series configuration, the flow of electric current remains uniform across every component. This behavior aligns with Kirchhoff's Voltage Law (KVL), which asserts that the total impedance in such a setup equals the sum of individual impedances—akin to resistors in series. It follows that the voltage from the power source is distributed proportionally among these components, adhering to the...
504
Raman Spectroscopy Instrumentation: Overview
532
A conventional Raman spectrophotometer includes a laser source, a sample holding system, a wavelength selector, and a detector.
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
The monochromatic laser source, typically using visible or near-infrared radiation, generates a highly focused beam of light. This light interacts with the molecules of the sample, scattering some of the light. Liquid and gaseous samples are usually tested in ordinary glass capillaries, while solids can be analyzed as powders packed in capillaries or as potassium...
532
Mass Analyzers: Common Types
705
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
705