冲击波压力测量和校准方法基于棒压力传感器
Yong-Xiang Shi1, Ying-Cheng Peng1, Yuan-Ding Xing1
1Northwest Institute of Nuclear Technology, Xi'an 710024, China.
Sensors (Basel, Switzerland)
|August 14, 2025
概括
这项研究引入了一种改进的方法,用于测量冲击波压力,使用条式压力传感器,光子多普勒测速仪 (PDV) 和应变测量. 新技术精确计算压力,克服了当前方法的局限性.
科学领域:
- 机械工程 机械工程
- 物理 物理学 物理
- 材料科学 材料科学 材料科学
背景情况:
- 当前酒吧压力传感器在准确测量冲击波压力方面存在局限性.
- 近场爆炸冲击波压力测量需要精确可靠的方法.
研究的目的:
- 设计一种改进的冲击波压力测量方法,克服现有的局限性.
- 验证开发的测量和校准系统的准确性和可靠性.
主要方法:
- 结合了棒压传感器与光子多普勒测速仪 (PDV) 和应变测量.
- 利用一维应力波理论,从测量的应力和粒子速度计算冲击波压力.
- 使用SHPB实验用于系统校准和验证.
主要成果:
- 改进的方法准确计算了对压力棒施加的冲击波压力.
- 应力波测量结果与各种波阻抗材料的理论计算保持一致.
- 在PDV和应变测量之间的峰值偏差小于1.5%.
结论:
- 开发的测量方法为冲击波压力提供了高精度.
- 建议的校准方法是可行的,并验证了测试系统的可靠性.
- 这种方法提高了相关应用中冲击波压力测量的精度.
相关概念视频
Measurement of Fluid Pressure
308
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
308
Definition and Measurement of Pressure: Atmospheric Pressure, Barometer, and Manometer
37.1K
Gas pressure is caused by force exerted by gas molecules colliding with the surfaces of objects. Although the force of each collision is very small, any surface of an appreciable area experiences a large number of collisions in a short time, which can result in high pressure.
37.1K
Pressure Gauges
4.0K
Most pressure gauges, like those on scuba tanks, are calibrated to read zero at atmospheric pressure. Readings from such gauges are called the gauge pressure, which is the pressure relative to atmospheric pressure. When the pressure inside the tank exceeds atmospheric pressure, the gauge reports a positive value. Some gauges are designed to measure negative pressure. For example, many physics experiments must take place in a vacuum chamber, a rigid chamber from which some of the air is pumped...
4.0K
Sound as Pressure Waves
2.5K
Sound waves, which are longitudinal waves, can be modeled as the displacement amplitude varying as a function of the spatial and temporal coordinates. As a column of the medium is displaced, its successive columns are also displaced. As the successive displacements differ relatively, a pressure difference with the surrounding pressure is created. The gauge pressure varies across the medium.
The pressure fluctuation depends on the difference in displacements between the successive points in the...
The pressure fluctuation depends on the difference in displacements between the successive points in the...
2.5K
Measurement of Blood Pressure
1.4K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
1.4K
Equipments Used To Measure Blood Pressure
2.3K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.3K