基于负序电流分析,检测反转式感应电机之间的间转短路故障
Sarvarbek Ruzimov1, Jianzhong Zhang1, Xu Huang1
1School of Electrical Engineering, Southeast University, Nanjing 210096, China.
Sensors (Basel, Switzerland)
|August 14, 2025
概括
这项研究引入了一种新方法,用于检测感应电机的间转短路故障. 该框架准确地识别和定位这些故障,提高发动机可靠性和预测性维护.
科学领域:
- 电气工程 电气工程
- 电力系统 电力系统
- 机器诊断 机器诊断 机器诊断
背景情况:
- 间转短路 (ITSC) 故障是感应电机常见的故障模式,导致性能降低和潜在故障.
- 早期检测ITSC故障对于防止灾难性故障和确保操作可靠性至关重要.
研究的目的:
- 开发和验证用于逆变器供电感应电机的强大的故障检测和定位框架.
- 为应对在各种操作条件下,包括变速和负载,准确识别ITSC故障的挑战.
主要方法:
- 使用负序列电流分析与基于波纹的过和对称组件分解相结合.
- 开发了一种新的故障检测指数,用于持续监测运动健康.
- 采用了负序电流基本组件的相角分析,用于故障定位.
主要成果:
- 拟议的框架在检测早期ITSC故障方面表现出高度敏感性.
- 实验验证证了在各种速度和负载条件下故障检测和定位的准确性.
- 该方法在逆变器供电的感应电机系统中被证明是有效的.
结论:
- 开发的框架提供了一个可靠的解决方案,用于实时监测感应电机的状态.
- 这种方法显著提高了系统可靠性,并通过预测性维护将计划外停机时间降到最低.
- 这种方法非常适合保护逆变器供电的电机系统免受ITSC故障的影响.
更多相关视频
11:53The Modular Design and Production of an Intelligent Robot Based on a Closed-Loop Control Strategy
Published on: October 14, 2017
11.8K
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
212
相关概念视频
Three-Phase Short Circuit—Unloaded Synchronous Machine
235
Conducting a three-phase short circuit test on an unloaded synchronous machine helps understand its impact on the system. The AC fault current's oscillogram, with the DC offset removed, reveals that the waveform amplitude decreases from an initially high value to a steady-state level for one phase of the machine.
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
235
Power System Three-Phase Short Circuits
149
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
149
Series R—L Circuit Transients
152
In a series resistor-inductor (R-L) circuit, closing the switch at the start of the time period simulates a three-phase short circuit, a fault condition where all three phases of an unloaded synchronous machine are short-circuited. When there is no fault impedance and no initial current, the initial voltage is determined by the phase angle of the source voltage.
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
Using Kirchhoff's Voltage Law (KVL) to analyze this circuit helps determine the total asymmetrical fault current, which consists...
152
Bus Impedance Matrix
175
Calculating subtransient fault currents for three-phase faults in an N-bus power system involves using the positive-sequence network. When a three-phase short circuit occurs at a specific bus, the analysis uses the superposition method to evaluate two separate circuits.
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
In the first circuit, all machine voltage sources are short-circuited, leaving only the prefault voltage source at the fault location. The positive-sequence bus impedance matrix can be determined by solving the nodal equations,...
175
Sequence Networks of Rotating Machines
140
A Y-connected synchronous generator, grounded through a neutral impedance, is designed to produce balanced internal phase voltages with only positive-sequence components. The generator's sequence networks include a source voltage that is exclusively in the positive-sequence network. The sequence components of line-to-ground voltages at the generator terminals illustrate this configuration.
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
Zero-sequence current induces a voltage drop across the generator's neutral impedance and other...
140
Fault Types
127
When analyzing a single line-to-ground fault from phase A to ground at a three-phase bus, it is important to consider the fault impedance. This impedance is zero for a bolted fault, equal to the arc impedance for an arcing fault, and represents the total fault impedance for a transmission-line insulator flashover. To derive sequence and phase currents, fault conditions are translated from the phase domain to the sequence domain.
For line-to-line faults occurring between phases B and C, the...
For line-to-line faults occurring between phases B and C, the...
127