在ECAP录音中延长脉冲阶段持续时间,以优化感知噪音
Tobias Raffelsberger1, Kathrin Lauss2, Thomas Rasse1
1Klinikum Wels-Grieskirchen, Wels, Austria.
International journal of audiology
|August 14, 2025
概括
在耳植入物 (CI) 电化合物作用电位 (ECAP) 测试中调整脉冲相位持续时间 (PD) 可以提高用户的舒适性. 较长的PD可以减少噪音感知,有利于敏感的CI用户.
科学领域:
- 听力学 听力学是指听力学.
- 生物医学工程 生物医学工程
- 神经科学是一个神经科学.
背景情况:
- 耳植入物 (CI) 使用电化合物作用电位 (ECAP) 来评估神经反应.
- 响度的敏感性可能会限制ECAP测量的有效性.
- 优化刺激参数,如脉冲阶段持续时间 (PD),可以提高用户的耐受性和数据质量.
研究的目的:
- 研究不同脉冲阶段持续时间 (PDs) 对ECAP值,噪音感知和CI用户测量成功率的影响.
- 为了确定调整PD是否可以改善ECAP测量的耐受性.
主要方法:
- 使用AutoART软件进行ECAP测量,PDs在30至100微秒之间.
- 声音感知与ECAP测量一起进行了评估.
- 20名MED-EL CI用户参与了这项研究.
主要成果:
- 较长的PD (80 & 100μs) 允许更高的最大刺激电荷,并被认为是较低的声音.
- ECAP和感知值都随着PD时间的延长而增加.
- 在所有经过测试的PD中,ECAP值确定率保持一致.
结论:
- 在ECAP测量中增加脉冲相位持续时间可以降低CI用户的噪音不适.
- 这种调整为临床听力学环境中的敏感CI用户提供了潜在的好处.
相关概念视频
Korotkoff Sounds
13.3K
Korotkoff sounds are the specific sounds heard while measuring blood pressure using a sphygmomanometer, typically with a stethoscope or a Doppler device. They are named after Russian physician Nikolai Korotkov, who first described them in 1905. These sounds correspond to turbulent blood flow in the artery as the blood pressure cuff is gradually released after inflation.
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
During blood pressure assessment, inflating the cuff 30 millimeters of mercury above the patient's systolic blood pressure...
13.3K
Echo
1.2K
The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
1.2K
Double Resonance Techniques: Overview
870
Double resonance techniques in Nuclear Magnetic Resonance (NMR) spectroscopy involve the simultaneous application of two different frequencies or radiofrequency pulses to manipulate and observe two distinct nuclear spins. One important application of double resonance is spin decoupling, which selectively suppresses coupling with one type of nucleus while observing the NMR signal from another nucleus, simplifying the spectrum and enhancing resolution.
Spin decoupling is usually achieved by...
Spin decoupling is usually achieved by...
870
Instrumentation Amplifier
1.3K
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
1.3K