基于超声波测试的桥梁管道中接紧密性的板厚尺寸影响的影响和验证
Chao Feng1, Miren Rong1,2, Yinping Pang3
1School of Urban Geology and Engineering, Hebei GEO University, Shijiazhuang, China.
PloS one
|August 14, 2025
概括
本研究介绍了一种精确的时间域分析模型,用于超声波非破坏性测试,以评估桥梁接的紧性. 该模型准确评估管道密度,考虑板厚的影响,以改善结构健康监测.
科学领域:
- 土木工程 土木工程是指土木工程.
- 材料科学 材料科学 材料科学
- 非破坏性测试是指非破坏性测试.
背景情况:
- 预应力桥管道需要可靠的接,以确保结构完整性.
- 超声波非破坏性测试 (NDT) 是评估内部结构条件的关键方法.
- 板厚可以影响NDT方法在检测接紧度时的准确性.
研究的目的:
- 为了研究板厚在超声波NDT上的尺寸影响,用于预应力桥管中接紧性.
- 开发和验证一个高精度的时间域分析模型来评估接密度.
- 为了提高预应力管道接损坏评估的准确性和效率.
主要方法:
- 使用ABAQUS有限元软件模拟混凝土中的超声波传播.
- 开发一个时间域分析理论模型,用于管道缺陷检测.
- 结合有限元模拟与工程案例验证进行模型验证.
主要成果:
- 拟议的时间域分析模型准确地评估了预应力桥管道的接紧性.
- 在高精度检测中,发现了板厚与第一波声学时间之间的强烈相关性.
- 该模型与实际的工程检测案例相比,显示出高可行性和可靠性.
结论:
- 时间域分析方法提供管道密度的准确定性和定量评估.
- 超声波NDT,当结合板厚效应时,显著改善了对接紧度的损坏评估.
- 这种方法提高了桥梁结构健康监测的整体效率和可靠性.
相关概念视频
Microcracking in Concrete
208
Microcracking in concrete refers to the tiny cracks that can form within the material even before any external load is applied. These microcracks typically occur at the interface between the coarse aggregate and the hydrated cement paste, often as a result of differential volume changes prompted by variations in stress-strain behavior, as well as thermal and moisture movement. Initially, these microcracks remain stable and do not grow substantially until the concrete is stressed to about 30...
208
Non-destructive Tests for Concrete Strength
193
The rebound hammer test, also known as the Schmidt hammer test, is a non-destructive technique for evaluating the hardness of concrete and, indirectly, the strength of concrete. It operates on the principle that the rebound of a spring-driven mass from a concrete surface correlates to the surface's hardness. The device comprises a mass within a tubular housing, a spring mechanism, and a plunger that strikes the concrete. Upon release, the energy imparted to the mass by the spring causes it...
193
Dynamic Modulus of Elasticity of Concrete
540
The dynamic modulus of elasticity assesses how a concrete structure deforms under impact or dynamic loads. It is typically higher than the static modulus of elasticity, measured under slow, steady loading conditions.
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
The sonic test is a common method to determine the dynamic modulus. In this test, a concrete beam, sized either 6 x 6 x 30 inches or 4 x 4 x 20 inches, is clamped at its center. Vibrations are initiated at one end of the beam by an electromagnetic exciter unit powered by...
540
Permeability of Concrete
214
Permeability in the context of concrete refers to how easily liquids or gases can pass through the material. This quality is crucial for assessing the water-tightness and durability of concrete structures and their resistance to chemical attacks. Concrete permeability can be determined through comparative laboratory tests. These tests typically involve sealing a concrete specimen from the sides, applying water pressure to the top surface with pressure, and measuring the amount of water passing...
214
Compacting Factor test
248
The compacting factor test is a method used to assess the workability of concrete. It is especially suitable for concrete mixes containing aggregates up to one and a half inches in size. This test involves specialized equipment consisting of two truncated cone-shaped hoppers and a cylinder, all with polished interior surfaces to minimize friction.
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
The procedure begins by placing concrete into the upper hopper without any compaction. Once filled, the bottom door of this hopper is opened,...
248
Testing Water Quality
185
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
185