相关实验视频
Updated: Sep 11, 2025

16:11
Implementation of a Reference Interferometer for Nanodetection
Published on: April 26, 2014
9.5K
交叉双微分散干涉测量,范围范围范围
Yang Wang1,2, Jindong Wang3, Jingsheng Huang4
1State Key Laboratory of Ultrafast Optical Science and Technology, Xi'an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi'an 710119, China.
Science advances
|August 15, 2025
概括
这项研究引入了一种新的交叉双微测距方法. 它消除了异步测量误差,并扩大了高精度距离测量的非模两可范围.
科学领域:
- 光学和光子学 在光学和光子学.
- 计量学 计量学 计量学
- 激光物理 激光物理
背景情况:
- 索利顿微是用于高精度测距的先进激光源.
- 高重复率虽然有利,但限制了非模两可的范围 (NAR).
- 现有的双方法扩展了NAR,但引入了异步测量误差 (AME),降低了准确性.
研究的目的:
- 提出一个交叉双微绝对范围方案.
- 在动态测量中消除AME.
- 扩展NAR以实现高精度,长距离的射程.
主要方法:
- 使用分散干扰计方法.
- 实现一个交叉双微配置.
- 使用一次性光谱采样来消除AME.
主要成果:
- 在动态测量过程中实现了AME的完全消除.
- 通过Vernier效应将NAR从3毫米延长到339米.
- 经过56秒的平均计算后,证明的艾伦偏差降至5.63纳米.
结论:
- 拟议的方案有效地消除了AME,并大大扩大了NAR.
- 该方法显示了直接集成芯片和最小检测器需求的潜力.
- 为未来的高精度,远距离射程和小型化激光雷达系统提供了先进的方法.
相关概念视频
Phase Contrast and Differential Interference Contrast Microscopy
9.5K
Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
9.5K
Electronic Distance Measuring Instruments
118
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over...
118
IR Spectrometers
1.5K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
1.5K
Two-Dimensional Microscopy in Microbiology
496
Two-dimensional (2D) microscopy encompasses a range of optical techniques that capture images within a single focal plane, offering detailed representations of microscopic structures. These techniques are essential in biological and medical research, enabling the visualization of cellular and subcellular structures with different levels of contrast and specificity.There are several major types of 2D microscopy, each with strengths and applications.Bright-Field MicroscopyBright-field microscopy...
496
Total Internal Reflection Fluorescence Microscopy
6.6K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
6.6K