相关实验视频
Updated: Sep 11, 2025

05:58
Plasma Lithography Surface Patterning for Creation of Cell Networks
Published on: June 14, 2011
12.8K
对等离子体复合频率选择性表面结构的宽带主动过特征的研究
Xinmin Han1, Shuangxin Wang2, Xiaolong Wei1
1National Key Lab of Aerospace Power System and Plasma Technology, Air Force Engineering University, Xi'an Shannxi, 710000, China.
Scientific reports
|August 16, 2025
概括
一种新的等离子复合频率选择面 (PC-FSS) 提供了可动态控制的广带过器. 这种主动过技术可以为先进的隐形应用提供可调节的带通和带停止特性.
科学领域:
- 电磁学和材料科学 电磁学和材料科学
- 等离子体物理与工程
背景情况:
- 雷多姆需要先进的过功能来进行动态控制.
- 现有的频率选择面 (FSS) 往往缺乏宽带和主动调能力.
研究的目的:
- 提出并演示具有宽带和主动过性能的等离子复合频率选择性表面 (PC-FSS).
- 调查血放电条件对PC-FSS性能的影响.
- 突出PC-FSS在活跃隐形雷达系统中的潜力.
主要方法:
- 设计了一种使用多层级级联络方法的宽带带通 FSS.
- 将FSS与感应合等离子体 (ICP) 集成,以创建PC-FSS.
- 进行实验测量,分析压力,功率和ICP厚度对过性能的影响.
主要成果:
- 通过调整排放条件,PC-FSS在广泛的频率范围内展示了可主动控制的过特性.
- 该结构表现出强烈的极化和角度稳定性.
- 在未激发状态下,它作为宽带带通波器 (8.0519.07 GHz) 运行.
- 当激发时,观察到可调的带通和带停止行为,提供切换和调功能.
结论:
- 开发的PC-FSS提供了一个可行的解决方案,用于宽带,动态可控制的过器在radomes.
- 通过等离子体放电条件来主动控制过特性经过实验验证.
- 该PC-FSS显示了重要的承诺,用于集成到活跃的隐形雷达系统.
相关概念视频
Active Filters
924
Active filters are electronic circuits that use operational amplifiers (op-amps), resistors, and capacitors to filter out unwanted frequency components from a signal. A first-order low-pass active filter is designed to pass signals with a frequency lower than a certain cutoff frequency and attenuate frequencies higher than that cutoff frequency. The transfer function for a first-order low-pass active filter is:
924
Passive Filters
607
Passive filters are utilized to shape the frequency spectrum of signals across a diverse array of applications. These filters, using only passive elements like resistors (R), inductors (L), and capacitors (C), are capable of selectively allowing or blocking certain frequency ranges without the need for external power sources.
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
Low-Pass Filters
Low-pass filters are designed to transmit signals with frequencies lower than the cutoff frequency, ωc, and attenuate those above it. The cutoff...
607
Plasma Membrane in Bacteria and Archaea
403
The plasma membrane is an essential cellular structure responsible for maintaining cellular integrity and regulating the selective transport of molecules. While bacteria and archaea share the fundamental function of plasma membranes, their structural and molecular differences reflect adaptations to distinct ecological and physiological challenges.Bacterial Plasma MembranesBacterial plasma membranes are predominantly composed of phospholipids with fatty acid chains ester-linked to a glycerol...
403
Fluid Mosaic Model
12.8K
Scientists identified the plasma membrane in the 1890s and its principal chemical components (lipids and proteins) by 1915. The model for plasma membrane structure, proposed in 1935 by Hugh Davson and James Danielli, was the first model to be widely accepted in the scientific community. The model was based on the plasma membrane's "railroad track" appearance in early electron micrographs. Davson and Danielli theorized that the plasma membrane's structure resembled a sandwich...
12.8K
Characteristics of Series Resonant Circuit
323
Series resonance occurs in a circuit containing inductive (L), capacitive (C), and resistive (R) elements connected sequentially. At the resonance frequency, the inductive and capacitive reactances are equal in magnitude but opposite in sign, effectively canceling each other. This causes the circuit's impedance is minimal, primarily determined by the resistance R. The resonant frequency of an RLC circuit is defined as:
323
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
296
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
296

