相关实验视频
Updated: Sep 10, 2025

07:36
Studying Cavitation Enhanced Therapy
Published on: April 9, 2021
5.3K
要求进行与船舶减速计划相关的水下辐射噪声的可比测量
Leila Hatch1, Megan McKenna2,3, Rianna Burnham4
1National Oceanic and Atmospheric Administration (NOAA) Office of National Marine Sanctuaries, 1305 East-West Highway, Silver Spring, Maryland 20910, USA.
JASA express letters
|August 20, 2025
概括
降低船舶速度 (VSR) 对于减少海洋噪音至关重要. 本研究评估了从北美VSR计划中测量降噪的方法,并建议改进调整以更好地评估和可持续航运.
科学领域:
- 海洋声学
- 海洋保护
- 海上运营
背景情况:
- 降低船舶速度 (VSR) 是减轻水下辐射噪声 (URN) 的一个关键策略.
- 区域VSR项目经常使用水下声学监测来评估降噪.
- 运营,经济和保护目标推动了对VSR的需求.
研究的目的:
- 评估目前在北美VSR计划中测量URN减少的方法.
- 记录强大的指标,可扩展的方法和综合性评估措施的进展.
- 确定改善VSR计划中的测量可比性的建议.
主要方法:
- 对北美VSR计划中使用的测量方法进行审查和评估.
- 关于减少 URN 的指标,方法和整合措施的进展记录.
- 对现有VSR计划数据和方法的分析.
主要成果:
- 在北美VSR项目中,测量URN减少的方法各不相同.
- 在发展指标和方法方面取得了进展,但缺乏标准化.
- 需要更好地协调,以确保VSR的有效性可比.
结论:
- 为了可比地测量URN减少,对VSR计划进行更好的调整至关重要.
- 标准化指标和方法将促进航天安全评估,并为可持续航运做出贡献.
- 加强VSR评估支持全球降低水下噪音的目标.
相关概念视频
Deriving the Speed of Sound in a Liquid
591
As with waves on a string, the speed of sound or a mechanical wave in a fluid depends on the fluid's elastic modulus and inertia. The two relevant physical quantities are the bulk modulus and the density of the material. Indeed, it turns out that the relationship between speed and the bulk modulus and density in fluids is the same as that between the speed and the Young's modulus and density in solids.
The speed of sound in fluids can be derived by considering a mechanical wave...
The speed of sound in fluids can be derived by considering a mechanical wave...
591
Pipe Flowrate Measurement
804
In pipe flow measurement, orifice, nozzle, and Venturi meters are commonly used to determine fluid flowrates by constricting the flow area, which increases fluid velocity and reduces pressure. This pressure difference, governed by Bernoulli's principle and adjusted for real-world conditions, is essential for calculating flowrate. Each meter type is suited to specific applications based on accuracy, efficiency, and compatibility with various flow conditions.
The orifice meter is a simple,...
The orifice meter is a simple,...
804
Equipments Used To Measure Blood Pressure
2.2K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
2.2K
Pipe Flowrate Measurement: Problem Solving
600
A spray tank system is engineered to uniformly distribute a pest-control liquid across plants by using a pressurized mechanism. The tank, pressurized to 150 kPa, holds the pesticide at a height of 0.80 meters. Liquid flows from the tank through a 1.9 meter pipe with a diameter of 0.015 meters, angled at 0.698 radians, ultimately reaching a 0.007 meter nozzle that sprays the pesticide. Accurate calculation of the system's flow rate is crucial to ensure uniform application, and this is...
600
Measurement of Fluid Pressure
306
Fluid pressure is commonly measured using devices called manometers, which rely on liquid columns to indicate pressure differences. The height of a liquid column in a manometer reflects the pressure exerted by the fluid, providing a simple yet effective means of measurement. Different types of manometers serve specific purposes based on their configurations and the type of fluids involved.
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
A basic form of manometer is the piezometer, a vertical tube open at the top and filled with the same...
306
Echo
601
The human ear cannot distinguish between two sources of sound if they happen to reach within a specific time interval, typically 0.1 seconds apart. More than this, and they are perceived as separate sources.
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
Imagine the sound is reflected back to the ears. Assuming that the source is very close to the human, the difference between hearing the two sounds—the emitted sound and the reflected sound—may be more than the minimum time for perceiving distinct sounds. If this is the case,...
601

