在不同品牌的包装性水中确定化物和PH度 - - 一项分析研究
Neha Pitale1, Riya Ramgade1, Karibasappa Gundabktha1
1Department of Public Health Dentistry, D. Y. Patil Dental School, Pune, Maharashtra, India.
概括
性水的pH值和含量在不同品牌之间有很大的差异. 消费者应该了解这些变化,以便在健康益处和水化方面做出明智的选择.
科学领域:
- 水质分析
- 公共卫生
- 消费者产品安全
背景情况:
- 性水的消费是受欢迎的健康益处.
- 最佳的化物和pH值对健康至关重要,
- 了解性水的成分对于消费者安全和有效性至关重要.
研究的目的:
- 评估各种性水中的化物度和pH值.
- 调查这些产品中的化物和pH值之间的关系.
- 确保性水产品符合消费者预期的质量标准.
主要方法:
- 六个不同的性水品牌被随机选择.
- 使用电化学探针测量化物度.
- 通过电测方法确定pH值.
主要成果:
- 平均化物度为0.212±0.376毫克/升,品牌差异很大 (0.021.03毫克/升).
- 平均pH值为7.754±0.672,通常低于制造商的说法,范围为7.05至8.66.
- 在化物和pH值之间发现了统计学上显著的负相关性 (P = 0. 032).
结论:
- 性水品牌在pH和含量方面表现出相当大的差异.
- 制造商应确保产品符合规定的pH值,并含有最佳的化物.
- 监管机构应强制执行标准,并要求明确标签以提高消费者意识.
更多相关视频
10:18Real-Time, Semi-Automated Fluorescent Measurement of the Airway Surface Liquid pH of Primary Human Airway Epithelial Cells
Published on: June 13, 2019
7.5K
08:21Optimized Procedure for Determining the Adsorption of Phosphonates onto Granular Ferric Hydroxide using a Miniaturized Phosphorus Determination Method
Published on: May 18, 2018
14.7K
相关概念视频
Determining the pH of Salt Solutions
44.1K
The pH of a salt solution is determined by its component anions and cations. Salts that contain pH-neutral anions and the hydronium ion-producing cations form a solution with a pH less than 7. For example, in ammonium nitrate (NH4NO3) solution, NO3− ions do not react with water whereas NH4+ ions produce the hydronium ions resulting in the acidic solution. In contrast, salts that contain pH-neutral cations and the hydroxide ion-producing anions form a solution with a pH greater than...
44.1K
Calculating pH Changes in a Buffer Solution
53.9K
A buffer can prevent a sudden drop or increase in the pH of a solution after the addition of a strong acid or base up to its buffering capacity; however, such addition of a strong acid or base does result in the slight pH change of the solution. The small pH change can be calculated by determining the resulting change in the concentration of buffer components, i.e., a weak acid and its conjugate base or vice versa. The concentrations obtained using these stoichiometric calculations can be used...
53.9K
pH Scale
70.3K
Hydronium and hydroxide ions are present both in pure water and in all aqueous solutions, and their concentrations are inversely proportional as determined by the ion product of water (Kw). The concentrations of these ions in a solution are often critical determinants of the solution’s properties and the chemical behaviors of its other solutes. Two different solutions can differ in their hydronium or hydroxide ion concentrations by a million, billion, or even trillion times. A common means of...
70.3K
Water: A Bronsted-Lowry Acid and Base
51.9K
The reaction between a Brønsted-Lowry acid and water is called acid ionization. For example, when hydrogen fluoride dissolves in water and ionizes, protons are transferred from hydrogen fluoride molecules to water molecules, yielding hydronium ions and fluoride ions:
51.9K
Mixtures of Acids
20.0K
The pH of a solution containing an acid can be determined using its acid dissociation constant and its initial concentration. If a solution contains two different acids, then its pH can be determined using one of several methods depending upon the relative strength of the acids and their dissociation constants.
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
A Mixture of a Strong Acid and a Weak Acid
In a mixture of a strong acid and a weak acid, the strong acid dissociates completely and becomes a source of almost all the hydronium ions...
20.0K
Testing Water Quality
182
When the quality of water for concrete preparation is uncertain, its impact on the setting time of cement and compressive strength of mortar is assessed by comparison with de-ionized or distilled water benchmarks. American Society for Testing and Materials (ASTM) C1602 requires the setting times to be within 90 minutes of the control, British Standard (BS) 3146:1980 allows a 30-minute variance in the initial setting, while British Standards European Norm (BS EN) 1008 specifies initial setting...
182