智能配送网络的高效自我修复框架
Fadheelah Meteab1,2, Behrouz Tousi1, Muammer Omran3,4
1Department of Electrical Engineering, Urmia University, Urmia, 5756151818, Iran.
Scientific reports
|August 24, 2025
概括
这项研究引入了智能电网的自我修复系统,提高了可靠性,减少了故障后的电力损失. 它使用先进的算法进行最佳的网络重新配置和分布式生成.
科学领域:
- 电气工程
- 电力系统工程
- 智能电网技术
背景情况:
- 智能分销网络需要强大的自我修复能力来保持可靠性.
- 电力系统的故障导致服务中断和电力损失增加.
研究的目的:
- 开发和验证智能分销网络的自我修复系统.
- 将故障检测,隔离和电源恢复与最佳网络重新配置相结合.
- 为了提高电压稳定性和运行效率.
主要方法:
- 在负载流量分析中使用了向后/向前扫描方法.
- 使用粒子集群优化来实现分布式发电机的最佳尺寸和位置.
- 使用 MATLAB/Simulink 和 CYME 在 IEEE 33 总线辐射分布系统上验证了系统.
主要成果:
- 在故障后实现快速服务恢复时间.
- 通过整合两个分布式发电机来减少电力损失.
- 显示了网络的最低电压情况的改善.
结论:
- 拟议的自我修复系统显著提高了网络可靠性和客户服务.
- 分布式发电机的集成提高了电压稳定性,减少了功率损失.
- 该系统为现代智能电网投资提供了可行和实用的解决方案.
相关概念视频
Distribution Reliability and Automation
155
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
155
Secondary Distribution
131
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
131
Primary Distribution
148
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
148
Distributed Loads: Problem Solving
731
Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
731
Reclosers and Fuses
162
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
162
Fast Decoupled and DC Powerflow
283
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
283