相关实验视频
Updated: Sep 10, 2025

10:33
Research and Development of High-performance Explosives
Published on: February 20, 2016
17.7K
气体爆炸的粉末抑制研究进展和发展趋势
Jinzhang Jia1,2, Yixue Zhang1,2, Peng Jia1,2,3
1College of Safety Science and Engineering, Liaoning Technical University, Fuxin, Liaoning 123000, China.
Langmuir : the ACS journal of surfaces and colloids
|August 26, 2025
概括
这项研究回顾了粉末爆炸抑制剂,详细说明了惰性,活性和复合粉末如何通过物理和化学机制抑制爆炸. 未来的研究应该集中在绿色粉末和现实的矿山条件上,以提高安全性.
科学领域:
- 化学工程
- 材料科学
- 安全工程
背景情况:
- 工业环境中的爆炸带来了重大风险.
- 粉末式防爆剂对于减轻这些危险至关重要.
- 了解抑制机制对于有效的安全策略至关重要.
研究的目的:
- 审查惰性,活性和复合粉末爆炸抑制剂的研究状况.
- 分析它们的爆炸特性和抑制机制.
- 确定未来的研究方向,以提高矿山安全.
主要方法:
- 关于粉末爆炸抑制剂的国内和国际研究的文献评论.
- 分析爆炸特性 (最大爆炸压力,火焰传播).
- 对不同类型的粉末的爆炸抑制机制的总结.
主要成果:
- 惰性粉末通过物理机制 (吸收热量,稀释氧气,物理屏障) 抑制爆炸.
- 活性粉末通过化学机制抑制爆炸 (捕获自由基).
- 复合粉具有协同的物理化学抑制作用.
结论:
- 粉末防爆剂通过不同的物理和/或化学途径起作用.
- 未来的研究必须优先考虑新的,绿色的,经济的粉末.
- 开发用于多领域合方案的抑制剂和整合新技术对于煤矿安全至关重要.
相关概念视频
Atomic Emission Spectroscopy: Interference
272
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
272
Gas Chromatography: Types of Detectors-II
498
In gas chromatography, different detectors are employed to meet specific analytical needs. These detectors are often categorized based on their detection mechanisms and the types of compounds they are best suited to analyze. Thermal Conductivity Detectors (TCD), Flame Ionization Detectors (FID), and Electron Capture Detectors (ECD) represent common categories, each with unique operating principles and applications. However, beyond these, several other detectors are designed for more specialized...
498
Flame Photometry: Overview
801
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
801
Atomic Absorption Spectroscopy: Atomization Methods
662
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
662
Atomic Absorption Spectroscopy: Interference
1.0K
Interference leads to systematic error in atomic absorption (AA) measurements by enhancing or diminishing the analytical signal or the background. These interferences can be grouped into three main categories: spectral interference, chemical interference, and physical interference.
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
1.0K

