瑞士分布式能源在未来的部署和灵活性
Lorenzo Zapparoli1, Alfredo Oneto1, María Parajeles Herrera2
1Reliability and Risk Engineering Laboratory, Institute of Energy and Process Engineering, Department of Mechanical and Process Engineering, ETH Zürich, Zürich, Switzerland.
Scientific data
|August 26, 2025
概括
一个新的数据库详细介绍了瑞士的分布式能源 (DER) 和负载,这对于在能源转型期间规划弹性电网至关重要. 这些数据支持电网监管和国家能源政策的制定.
科学领域:
- 能源系统工程
- 电力系统分析
- 计算社会科学
背景情况:
- 全球脱碳努力需要电力分配网的能源转型.
- 由于可再生能源的整合,电网面临越来越多的波动性和运营压力.
- 缺乏分布式能源 (DER) 的细节数据阻碍了有效的电网规划和监管.
研究的目的:
- 创建瑞士配电网中的DER和不可控制负载的综合数据库.
- 为电网规划和监管提供高时间和空间分辨率的数据.
- 通过详细说明灵活性能力,支持电网弹性和能源政策的研究.
主要方法:
- 汇编瑞士中低压配电网模型的数据
- 包含超过200万个连接点,指定可控制的设备灵活性.
- 制定与2030年,2040年和2050年的国家能源预测相一致的预测.
主要成果:
- 已经建立了瑞士配电网上的DER和负载的综合数据库.
- 该数据库量化可控制设备的灵活性潜力.
- 到2050年的预测为未来的电网场景提供了洞察力.
结论:
- 该数据库对于理解和管理不断变化的能源环境至关重要.
- 它的模块化结构可以从地方到国家层面进行可扩展的分析.
- 促进DER整合,电网弹性和明智的能源政策决策的研究.
相关概念视频
Secondary Distribution
131
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
131
Transformers in Distribution System
156
Transformers in distribution systems can be broadly categorized into distribution substation transformers and other distribution transformers. They are crucial for stepping down high transmission voltages to levels suitable for distribution and end-user applications.
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
Distribution substation transformers come in various ratings and typically use mineral oil for insulation and cooling. To prevent moisture and air from entering the oil, some transformers use an inert gas like nitrogen to fill the...
156
Distribution Reliability and Automation
155
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
155
Power System Distribution
313
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
313
Fast Decoupled and DC Powerflow
283
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
283
Energy Line and Hydraulic Gradient Line
1.4K
Based on Bernoulli's equation, the energy line (EL) and hydraulic grade line (HGL) provide graphical representations of energy distribution in a fluid flow system. For steady, incompressible, inviscid flows, Bernoulli's equation is expressed as:
1.4K