平均场跳转扩散系统的环形有限时间H2/H∞控制
IEEE transactions on cybernetics
|August 27, 2025
概括
本研究介绍了复杂的跳转扩散系统的环形有限时间H2/H∞控制. 这种新方法确保了系统的稳定性,并优化了性能指数,优于现有的有限时间控制策略.
科学领域:
- 控制理论
- 随机系统
- 非线性动力学
背景情况:
- 中场跳转扩散系统 (MFJDS) 涉及连续 (Wiener) 和离散 (Poisson) 噪声过程.
- 确保这些复杂系统的有限时间稳定性和性能是一个重大挑战.
研究的目的:
- 介绍和分析MFJDS的环形有限时间H2/H∞控制.
- 开发状态反和基于观察者的环形有限时间H2/H∞控制的新条件.
- 提出一个新的参数分析和性能优化的算法.
主要方法:
- 在平均平方意义上定义环形有限时间局限性 (AFTB).
- 获得足够的状态反和基于观察者的控制条件.
- 为确定稳定性参数和性能权衡开发算法.
主要成果:
- 拟议的环形有限时间H2/H∞控制确保了AFTB并将H2/H∞指数最小化.
- 建立了对状态反和基于观察者的控制较为保守的条件.
- 设计的算法有效地确定稳定范围和性能关系.
结论:
- 新的环形有限时间H2/H∞控制为MFJDS提供了卓越的性能.
- 提出的方法和算法为系统设计和分析提供了实用工具.
- 通过综合设计示例证明了实际优势.
相关概念视频
Transmission-Line Differential Equations
401
Transmission lines are essential components of electrical power systems. They are characterized by the distributed nature of resistance (R), inductance (L), and capacitance (C) per unit length. To analyze these lines, differential equations are employed to model the variations in voltage and current along the line.
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured...
Line Section Model
A circuit representing a line section of length Δx helps in understanding the transmission line parameters. The voltage V(x) and current i(x) are measured...
401
Second Order systems II
171
In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
171
Conservation of Energy in Control Volume
908
Consider a turbine operating under steady-flow conditions. The control volume is drawn around the turbine, with fluid entering at one point and exiting at another. The turbine extracts energy from the fluid, which performs mechanical work (shaft work).
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
For steady flow systems, the time derivative of the stored energy becomes zero since there is no energy accumulation within the control volume. This simplifies the energy equation to:
908
Conservation of Mass in Finite Cotrol Volume
1.4K
The principle of conservation of mass is a fundamental law in fluid mechanics and is applied using the continuity equation. We apply the concept to a finite control volume to derive the continuity equation.
A system is defined as a collection of unchanging contents, and the conservation of mass states that a system's mass is constant.
A system is defined as a collection of unchanging contents, and the conservation of mass states that a system's mass is constant.
1.4K
Feedback control systems
416
Feedback control systems are categorized in various ways based on their design, analysis, and signal types.
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
Linear feedback systems are theoretical models that simplify analysis and design. These systems operate under the principle that their output is directly proportional to their input within certain ranges. For instance, an amplifier in a control system behaves linearly as long as the input signal remains within a specific range. However, most physical systems exhibit inherent nonlinearity...
416
BIBO stability of continuous and discrete -time systems
511
System stability is a fundamental concept in signal processing, often assessed using convolution. For a system to be considered bounded-input bounded-output (BIBO) stable, any bounded input signal must produce a bounded output signal. A bounded input signal is one where the modulus does not exceed a certain constant at any point in time.
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
511