用电子束辐射在水溶液中有效降解抗生素
Anastasia Oprunenko1, Ulyana Bliznyuk2,3, Victoria Ipatova3
1Department of Chemistry, Lomonosov Moscow State University, GSP-1, 1-3 Leninskiye Gory, 119991 Moscow, Russia.
Antibiotics (Basel, Switzerland)
|August 28, 2025
概括
电子束辐射有效地从水中去除98-99%的抗生素残留物. 这项研究通过分析抗生素降解率来确定水处理的最佳辐射剂量.
科学领域:
- 环境科学
- 分析化学
- 辐射化学
背景情况:
- 由于广泛使用, 抗生素残留物会污染自然水系统.
- 制药污染对环境和健康构成重大风险.
研究的目的:
- 通过电子束辐射在水溶液中研究常见抗生素 (青素,四环素,素) 的降解.
- 为了确定不同辐射剂量的抗生素去除效果.
- 开发一种量化标志物来评估抗生素降解.
主要方法:
- 在0.1,1,3和7kGy的剂量中暴露于1MeV加速电子的抗生素溶液中.
- 使用高性能液体染色学高分辨率质谱法 (HPLC-HRMS) 分析抗生素降解.
- 开发一个数学模型来描述剂量依赖的降解动力学和辐射敏感性.
主要成果:
- 在7kGy的辐射中,可以实现98-99%的抗生素去除 (初始度为15-30mg/L).
- 与其他抗生素相比,四环素的辐射化学产量更高.
- 数学模型揭示了与抗生素类辐射敏感性相关的不同分解速率.
结论:
- 使用密度函数理论和数学模型开发了一种抗生素降解的新型定量标记.
- 这种方法可以确定抗生素降解程度,并优化工业用水处理的辐射剂量.
相关概念视频
Physical Methods for Controlling Microbial Growth: Radiation and Filtration
218
Radiation and filtration are essential tools for microbial control, targeting microorganisms through distinct mechanisms. Radiation eliminates microbes by damaging their DNA, either killing them or inhibiting their growth. Based on wavelength, radiation is classified into two types: nonionizing and ionizing radiation.Non-ionizing radiation, such as UV radiation (200–400 nm), is absorbed by DNA, causing defects that effectively disinfect surfaces, air, and water, including safety cabinets.
218
Antimicrobial Effectiveness
156
The effectiveness of antimicrobial agents depends on various factors influencing their ability to eliminate microbial populations. Larger microbial populations require more time for complete eradication, emphasizing the importance of population size analysis when evaluating antimicrobial efficacy.Microbial resistance to antimicrobial agents varies significantly. Highly resilient microorganisms include endospores, gram-negative bacteria, and non-enveloped viruses, while prions are exceptionally...
156
Methods of Sterilization II: Chemical Methods
6.9K
In healthcare, the chemical method of sterilization uses chemical sterilants to treat surgical instruments and medical supplies to help prevent the transmission of infectious pathogens to patients. Due to heat sensitivity, most medical supplies and equipment should not be exposed to high temperatures. These parts include rubber, plastic, glass, and other similar elements.
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
Using chemical sterilization rather than heat to clean out equipment is recommended. It eradicates and removes all bacteria,...
6.9K
Chemical Agents for Microbial Control
199
Chemicals play important roles in controlling microbial growth by targeting microbial structures and functions as sanitizers, antiseptics, disinfectants, and sterilants.Alcohols are commonly used sanitizers, effectively disrupting lipid membranes, which compromises cell integrity. They are also used as antiseptics and disinfectants due to their rapid action and versatility.Phenols and their derivatives phenolics , known for denaturing proteins and disrupting cell membranes, are particularly...
199
Biological Methods for Microbial Control
199
Biological agents offer an effective means of controlling microbial growth by leveraging natural processes like predation, competition, and the secretion of antimicrobial substances.Predatory bacteria such as Bdellovibrio species target and kill pathogens like Salmonella and E. coli. They are widely used in poultry farms to control infections. Myxococcus species help combat plant-pathogenic fungi. These naturally occurring predators serve as eco-friendly alternatives to chemical pesticides and...
199
Methods of Sterilization I: Physical Methods
20.8K
As used in a healthcare facility, sterilization destroys all microorganisms through physical or chemical methods. The physical method includes steam, dry heat, boiling water, and radiation.
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
Steam sterilization uses non-toxic, low-cost moist heat in the form of saturated steam under pressure, which is fast, microbicidal, and sporicidal, and quickly warms and penetrates fabrics. Autoclaves, or steam sterilizers, expose each item to direct steam contact for a predetermined time at the necessary...
20.8K