对高强度混凝土机械性能的影响研究
Marek Miazgowicz1, Lucyna Domagała2
1CUT Doctoral School, Faculty of Civil Engineering, Cracow University of Technology, 31-155 Kraków, Poland.
Materials (Basel, Switzerland)
|August 28, 2025
概括
样品的形状和尺寸对高强度混凝土的性能影响最小. 混凝土的内部结构和密度是影响其弹性模量和压力强度的主要因素.
科学领域:
- 材料科学
- 土木工程
- 混凝土技术
背景情况:
- 欧洲标准EN 12390-13允许混凝土测试各种样品形状和尺寸.
- 现有的标准缺乏关于样品几何和弹性模块之间的关系的指导.
- 样品尺寸的变化可能会影响混凝土的测量机械性能.
研究的目的:
- 研究样品形状和尺寸对高强度混凝土弹性模量和压力强度的影响.
- 根据样品几何形状量化测量弹性模量 (动态和切割) 和压力强度的差异.
- 确定样品尺寸与材料结构对混凝土机械行为的相对重要性.
主要方法:
- 测试 64 个高强度混凝土样本 (平均强度为 101.9 MPa).
- 使用不同尺寸和细度的立方体和圆柱体样本.
- 将不同样本几何形状的结果与标准圆柱形样本 (150 × 300 mm) 相比较.
主要成果:
- 与标准气相比,动态弹性模量 (Ed) 的差异高达19%,断裂模量 (Ec,s) 高达14%.
- 样品的尺寸和形状对机械性能的影响较小.
- 混凝土的内部结构和密度被确定为影响测量的主要因素.
结论:
- 高强度混凝土的个体结构和密度是其弹性模量和压力强度的关键决定因素.
- 样品的形状和尺寸对测量的机械性质的影响相对较小.
- 在混凝土测试中对样品几何的标准化可能需要根据材料特征进行重新评估.
相关概念视频
Fatigue Strength of Concrete
284
Fatigue, in the context of materials science and engineering, refers to the weakening or failure of a material caused by repeatedly applied loads, even if these loads are below the strength limit of the material. Fatigue strength in concrete is a critical property that influences its durability and longevity. Concrete can fail in two ways due to fatigue. Static fatigue or creep rupture occurs under a constant load or one that increases slowly. The other failure mode is due to cyclical or...
284
Tensile Strength Considerations of Concrete
194
Considering the tensile strength of concrete involves recognizing that the theoretical strength of cement paste can be up to a thousand times higher than what is observed in practical applications. This significant discrepancy is largely attributed to the presence of microscopic cracks within the concrete. These cracks tend to amplify stress at their tips when a load is applied, a phenomenon explained by Griffith's theory of brittle fracture.
The dimensions and shape of a concrete specimen...
The dimensions and shape of a concrete specimen...
194
Relation Between Tensile Strength and Compressive Strength of Concrete
347
Concrete is a fundamental building material, and understanding its strengths is crucial for construction projects. The relationship between its tensile and compressive strengths is intricate, showing that while these strengths are related, they do not increase at the same rate. Tensile strength's growth is slower and is affected by various factors such as the methods used for testing, the size and shape of the specimen, the texture of the aggregate used, and the moisture content of the...
347
Impact Strength of Concrete
326
Impact strength in concrete is a critical measure that reflects the material's capability to endure the forces applied during pile driving and when supporting machinery foundations that experience impulsive loads. It is also essential when handling precast concrete components to prevent accidental damage. The impact strength is assessed by observing the concrete's resistance to repeated impacts and energy absorption capacity. A key indicator of significant damage to concrete is when it...
326
Elasticity in Concrete
133
Upon subjecting concrete to moderate or high uniaxial compressive or tensile stresses, the strain response is non-linear relative to the stress applied. As the stress is removed, the resulting stress-strain curve deviates from the original path traced during loading, creating a hysteresis loop, indicative of the concrete's non-linear and non-elastic properties. Typically, a material's modulus of elasticity, which is a measure of the material's stiffness, is inferred from the linear...
133
Effects of Air-entrainment in Concrete
140
Air entrainment in concrete significantly enhances the material's durability, especially in environments subjected to freeze-thaw cycles. Introducing small air bubbles into the concrete mix acts as internal voids that accommodate the expansion of water when it freezes, thereby alleviating internal stress and preventing structural cracks. This function is crucial in climates with significant freezing and thawing, as it protects the concrete from repeated stresses that could lead to premature...
140