相关实验视频
Updated: May 2, 2026

07:51
Video Movement Analysis Using Smartphones ViMAS: A Pilot Study
Published on: March 14, 2017
16.9K
使用智能手机嵌入式传感器测量乳房高度的高精度直径
Wang Xiang1, Songlin Fei2, Song Zhang1
1School of Mechanical Engineering, Purdue University, West Lafayette, IN 47907, USA.
Sensors (Basel, Switzerland)
|August 28, 2025
概括
这项研究引入了一种使用iPhone 13 Pro的新方法来估计乳房高度的树直径 (DBH). 这种新的方法利用内置的LiDAR和RGB传感器进行准确和用户友好的森林测量.
科学领域:
- 森林管理
- 遥感技术
- 计算机视觉
背景情况:
- 准确的树木直径在胸高 (DBH) 估计对于森林库存和管理至关重要.
- 传统的DBH测量方法可能耗时,需要专门的工具.
- 移动传感器技术的进步为更容易获得的森林测量解决方案提供了潜力.
研究的目的:
- 开发和验证使用iPhone 13 Pro集成的LiDAR和RGB传感器估计树DBH的新方法.
- 提高森林环境中DBH测量的准确性和现场可用性.
- 展示使用消费级移动设备来精确测量森林的可行性.
主要方法:
- 一个快照捕获深度 (LiDAR) 和RGB图像,生成树的3D点云.
- 从点云估计干部的方向,以准确地定位乳房高度 (1.3米).
- 最初的DBH估计使用几何关系,并通过预先计算的查找表 (LUT) 改进以提高准确性.
主要成果:
- 该方法实现了0.53厘米的平均绝对误差 (MAE) 和0.63厘米的根平均平方误差 (RMSE).
- 在各种大小的树木和捕获距离 (0. 25米至5米) 中,成功估计了DBH.
- 这种方法在捕捉角度的变化中被证明是可靠的,而不依赖于用户的定位.
结论:
- iPhone 13 Pro 的 LiDAR 和 RGB 传感器为准确和高效的树 DBH 估计提供了可行的工具.
- 这项技术可显著提高森林库存和管理应用的现场可用性.
- 开发的方法代表了传统森林测量技术的成本效益和可访问的替代方案.
相关概念视频
Equipments Used to Measure Body Temperature
2.1K
Body temperature can be assessed using various devices and measured in Celsius or Fahrenheit.
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
2.1K
Assessing Body Temperature - Axilla
1.9K
Procedural Guide for Assessing Axillary Body Temperature using a Digital Thermometer:
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
1.9K
Sites for measuring blood pressure
3.9K
Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
The Brachial Artery: Primary Site for Blood Pressure Measurement
3.9K
Equipments Used To Measure Blood Pressure
3.4K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.4K
Special considerations while measuring blood pressure
1.5K
When assessing blood pressure (BP), healthcare professionals must consider various factors and potential unexpected outcomes to ensure accurate readings and provide proper patient care. Adhering to these guidelines is essential to achieving the most reliable results.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
1.5K
Measurement of Blood Pressure
4.0K
Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a...
4.0K

