活动类型 影响心电图装置中的信号质量
Bryndan Lindsey1, Samantha Snyder2, Yuanyuan Zhou3
1Johns Hopkins Applied Physics Laboratory (JHU/APL), Laurel, MD 20723, USA.
Sensors (Basel, Switzerland)
|August 28, 2025
概括
商用心电图 (ECG) 设备在动态活动中显示不同的信号质量. 与Zephyr BioHarness 3.0相比,Polar H10在各种练习中表现得更强.
科学领域:
- 生物医学工程
- 运动科学
- 生理监测
背景情况:
- 电心电图 (ECG) 设备对于监测心率和心率变化 (HRV) 是至关重要的.
- 穿戴式心电图设备的信号质量可能会在非直立活动中降低,原因是运动器件和肌肉干扰.
- 现有的验证协议可能无法充分反映现实,动态的使用场景.
研究的目的:
- 在各种身体活动中比较三种商业胸部佩戴设备和多导线心电图监测器的心电图信号质量.
- 评估不同类型的活动 (跑步机上行走,循环训练,障碍赛道) 对心电图信号完整性的影响.
- 在动态,非垂直条件下保持优异信号质量的设备.
主要方法:
- 使用Polare H10,Equivital EQ-02,Zephyr BioHarness 3.0和BIOPAC设备的节拍信号质量指数进行信号质量比较.
- 在跑步机上行走,循环训练和障碍物课程中评估心电图表现.
- 根据SQI值 (<0.7) 和生理可信度计算的信号拒绝率.
主要成果:
- 设备类型和活动都显著影响了心电图信号质量 (p < 0. 001).
- 与跑步机上行走相比,在障碍物赛道和电路训练中观察到更高的信号排斥率 (p < 0. 01).
- 与Polar H10和BIOPAC相比,Zephyr BioHarness 3.0的排斥率更高;Polar H10的平均排斥率更低.
结论:
- 动态,非直立活动显著影响商业设备的心电图信号质量.
- 与Zephyr BioHarness 3.0相比,Polar H10在各种活动中表现出更强大的稳定性.
- 对心电图装置的验证协议应包含现实,动态的任务,以反映现实世界的性能.
更多相关视频
18:11A Research Method For Detecting Transient Myocardial Ischemia In Patients With Suspected Acute Coronary Syndrome Using Continuous ST-segment Analysis
Published on: December 28, 2012
24.4K
04:33Effects of Different Connection Modes of Electroacupuncture on Electrocardiogram and Nerve Discharge in Rats
Published on: January 3, 2025
308
相关概念视频
Electrocardiogram
3.2K
An electrocardiogram (ECG or EKG) is a critical diagnostic tool that records the electrical signals produced by the heart during each heartbeat. This recording is achieved through electrodes placed strategically on the arms, legs, and chest. The electrocardiograph amplifies these signals and produces 12 distinct tracings, offering a comprehensive understanding of the heart's electrical activity.
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and...
3.2K
Instrumentation Amplifier
695
An electrocardiography (ECG) machine is an essential piece of medical equipment used to monitor the electrical activity of the heart. It operates by detecting small electrical changes on the skin that result from the depolarization of the heart muscle during each heartbeat. However, these signals are in the microvolt range and can be easily overwhelmed by noise or interference.
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
695
Electrocardiogram Fundamentals
868
Introduction
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...
868
Pulse rhythm
925
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
925
Bode Plots Construction
785
The Bode plot is an essential tool in control system analysis, mapping the frequency response of a system through a magnitude plot and a phase plot, both against a logarithmic frequency axis. To construct a Bode plot, consider the transfer function H(ω):
785
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
160
Arrhythmia is a condition characterized by an irregular heart rhythm, with ECG changes that differ based on its origin and nature. The types of arrhythmias discussed below include atrial, junctional, and ventricular arrhythmias.Atrial ArrhythmiasPremature Atrial Complexes (PACs): PACs are early atrial beats caused by stress, caffeine, alcohol, electrolyte imbalances, hypoxia, hyperthyroidism, or certain medications (e.g., bronchodilators and decongestants). The ECG shows early P waves with an...
160