分散太阳能发电可提高可靠性,减少排放并避免滞留资产的机会
Philip Sandwell1,2, Benedict Winchester1,2,3, Shivika Mittal2,4
1Department of Physics, Imperial College London, London, UK.
Nature communications
|August 28, 2025
概括
连接到国家电网的小型太阳能电网提高了电力可靠性,并降低了低收入国家的成本. 然而,需求减少带来经济风险,需要支持可持续投资的政策.
科学领域:
- 能源系统工程
- 可再生能源政策
- 可持续的发展
背景情况:
- 尽管有所改善,但电力供应的可靠性仍然是低收入国家的挑战.
- 当地可再生能源基础设施,如太阳能光伏 (PV) 微型电网,为农村社区提供了解决方案.
- 由于潜在的客户损失,国家电网的增强可能会给可再生能源资产带来投资风险.
研究的目的:
- 探索太阳能光伏小型电网与国家电网的互连.
- 评估与小型电网电力需求减少相关的投资风险.
- 评估连接到电网的小型电网对电力成本,可靠性和碳强度的影响.
主要方法:
- 使用能源系统建模来模拟小型电网和国家电网的相互作用.
- 该研究分析了不同电力需求水平对经济可行性的影响.
- 进行了投资风险和环境效益的量化.
主要成果:
- 连接到国家电网的小型电网可以降低单位电力成本并提高可靠性.
- 这些系统有助于减少碳强度,符合可持续发展目标7.
- 电力需求的适度减少严重威胁到小电网的经济可行性.
结论:
- 将太阳能光伏小型电网与国家电网相连,是提高能源获取和可持续性的可行策略.
- 政策干预对于减轻投资风险和鼓励采用连接到电网的小型电网至关重要.
- 改善电网可靠性与当地可再生能源投资的经济可持续性之间的平衡至关重要.
更多相关视频
相关概念视频
Distribution Reliability and Automation
153
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
153
P-N junction
673
A p-n junction is formed when p-type and n-type semiconductor materials are joined together. At the interface of the p-n junction, holes from the p-side and electrons from the n-side begin to diffuse into the opposite sides due to the concentration gradient. This diffusion of carriers leads to a region around the junction where there are no free charge carriers, known as the depletion region. The charge density within the depletion region for the n-side and p-side can be described by the...
673
Fast Decoupled and DC Powerflow
282
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
282
Secondary Distribution
130
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
130
Conservation of AC Power
389
The principle of power preservation is applicable to both ac and dc circuits. This principle, when applied to AC power, asserts that the complex, real, and reactive powers produced by the source are equal to the total complex, real, and reactive powers absorbed by the loads. When two load impedances are connected in parallel to an ac source V, the complex power provided by the source can be calculated using the relation
389
Power System Distribution
312
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
312