基于水流的高压水脱的传热系数预测模型
Peng Gao1, Yue Zhuo2, Guodong Sun3
1Peng Gao, School of Mechanical and Intelligent Manufacturing, Jiujiang University, Jiujiang, 332005, China. gaopeng20060707@163.com.
Scientific reports
|September 1, 2025
概括
这项研究开发了一种新的数学模型,用于准确预测高压水脱的热传递系数 (HTC),改进温度场分析并通过工业数据验证.
科学领域:
- 材料科学与工程
- 热传递和流体动力学
- 计算模型
背景情况:
- 现有热传递系数 (HTC) 的公式显示了高压水脱的差异.
- 不准确的HTC计算导致了脱温度场分析的错误.
研究的目的:
- 系统地调查影响HTC高压水脱的操作变量.
- 在这些过程中开发HTC预测的实用数学模型.
- 通过实验验证模型的准确性.
主要方法:
- 水流和表面温度的参数分析.
- 计算流体动力学 (CFD) 模拟来评估HTC.
- 使用非线性回归分析开发预测数学模型.
- 有限元素分析 (FEA) 用于热概况模拟.
- 红外热学用于实时温度验证.
主要成果:
- 开发了一种基于HTC高压水脱的新型回归数学模型.
- CFD和FEA模拟提供了定量HTC评估和热谱.
- 工业验证显示温度差异最大为28°C,最小为1°C.
- 与实验数据相比,该模型的预测准确度很高.
结论:
- 新的数学模型准确地预测HTC在高压水中脱.
- 该模型提高了工业脱操作中的热谱分析的准确性.
- 这项研究为优化高压水脱工艺提供了可靠的工具.
相关概念视频
Typical Model Studies
440
Fluid mechanics model studies often utilize scaled-down systems to predict fluid behavior in full-scale environments, such as river flows, dam spillways, and structures interacting with open surfaces. Maintaining Froude number similarity in river models is crucial, as it replicates surface flow features like wave patterns and velocities.
440
Design Example: Creating a Hydraulic Model of a Dam Spillway
286
Scaled hydraulic models of dam spillways provide a practical way to replicate and study the intricate flow dynamics of these structures. Often built to a 1:15 ratio, these models allow for observing critical water behavior, such as velocity distribution, flow patterns, and energy dissipation.
286
Design Example: Designing a Residential Plumbing System
788
The design of residential plumbing systems requires carefully evaluating water demand, flow rates, and pressure dynamics to ensure both efficiency and reliability. The nature of water flow within pipes is defined by its Reynolds number, which classifies flow as either laminar (smooth) or turbulent.
788
Major Losses in Pipes
1.3K
When a fluid flows through a pipe, it experiences energy losses due to frictional resistance along the pipe walls, known as major losses. These energy losses result in a pressure drop, which varies based on the flow conditions — whether laminar or turbulent — and the specific physical properties of the fluid and pipe.
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to...
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to...
1.3K
Fluid Pressure over Flat Plate of Variable Width
1.8K
When a flat plate is submerged in a fluid, the fluid exerts pressure on the plate. This pressure can lead to many different phenomena, including drag and buoyancy. To understand the behavior of the fluid over a flat plate of variable width, it is essential to analyze the distribution of the pressure exerted.
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
1.8K
Single Pipe Systems
191
In pipe flow analysis, problems are typically categorized into three types — Type I, Type II, and Type III — based on the known parameters and the desired outcome. Each type of problem addresses specific engineering requirements using fluid properties, pipe characteristics, and operational conditions.
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
In a Type I problem, fluid properties (density and viscosity), pipe characteristics (including diameter, length, and surface roughness), and the flow rate or average velocity are...
191


