概括
这项研究引入了跨度层次的超表面 (THM) 来增强光学传输和电磁散射控制. 新的超表面设计实现了超过90%的透射率和显著的雷达截面减少,用于先进的光学和微波应用.
科学领域:
- 超材料和纳米光子
- 电磁波操纵
- 多功能光学设备
背景情况:
- 由于材料和结构不匹配,控制光学窗户中的电磁散射对于多光谱和广角应用具有挑战性.
- 现有的解决方案往往会损害光学传输或电磁兼容性.
研究的目的:
- 开发跨尺度的层次化超表面 (THM) 以同时进行广角光学传输增强和电磁散射调节.
- 在红外,微波和双频激光范围内实现兼容性.
主要方法:
- 使用多级纳米光刻法制造THM,包括超细空心金属阵列 (UHMA) 和增强传输的微纳米阵列 (TMCA).
- 微波雷达截面 (RCS) 的回声扩散反射控制的UHMA.
- TMCA用于广角光学传输增强.
主要成果:
- 在9.5-17.5GHz微波频段中已证明减少了10dB的散射.
- 在1.42μm,1.7μm和3-5μm的光学范围下达到超过90%的平均光学传导率.
- 与使用UHMA的硫化 (ZnS) 窗口相比,大角度的平均传输率提高了34.3%.
结论:
- THM提供了卓越的多功能兼容性和光学性能,用于协同光学和微波调节.
- 开发的超表面为微波设备的光学透明度提供了可行的解决方案.
- 证明了宽带偏离独立,低交叉成像和疏水特性.
相关概念视频
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
7.8K
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for...
7.8K
UV–Vis Spectroscopy: Beer–Lambert Law
7.6K
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
7.6K
UV–Vis Spectrometers
4.1K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
4.1K
IR Spectrometers
3.1K
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
3.1K
Total Internal Reflection Fluorescence Microscopy
11.0K
Total internal reflection fluorescence microscopy or TIRF is an advanced microscopic technique used to visualize fluorophores in samples close to a solid surface with a higher refractive index, such as a glass coverslip. TIRF only allows fluorophores in proximity to the solid surface to be excited. When light from a medium with a lower refractive index (such as air) hits the glass coverslip at a critical angle, the light undergoes total internal reflection stead of passing through the glass.
11.0K