测量绝对光分离和光解离截面的快速和精简的方法
Salvi Mohandas1, Uma Namangalam1, Abheek Roy1
1Department of Physics and CAMOST, IISER Tirupati, 517619 Andhra Pradesh, India.
The Journal of chemical physics
|September 4, 2025
概括
研究人员开发了一种更快的方法来测量光分离截面,这对于了解分子离子稳定性至关重要. 这种技术成功地应用于无质子的,一个生物相关的分子.
科学领域:
- 物理化学
- 化学物理
- 分子光谱学
背景情况:
- 绝对光分离的截面量化了阳离子的光稳定性.
- 之前的测量仅限于原子和简单分子离子.
- 在2006年建立了一种离子陷技术来测量这些截面.
研究的目的:
- 为了简化绝对光隔断截面的测量.
- 显著减少分子离子的测量时间.
- 能够对生物相关分子进行测量.
主要方法:
- 一种结合实验速率测量与模拟离子密度分布的新方法.
- 通过复制已知的OH-光分离截面来验证精简的技术.
- 该方法应用于403 nm的无质子.
主要成果:
- 建议的技术将测量时间缩短数量级.
- 这是第一次测量了无质子的绝对光分离截面.
- 这一方法的可复制性证实了OH截面测量的有效性.
结论:
- 简化技术对创建光隔断截面数据库产生了变革性影响.
- 测量可以推动对截面计算的计算代码的进步.
- 这项工作增强了对大分子中的电子动态和光物质相互作用的理解.
更多相关视频
09:40Measurement and Analysis of Atomic Hydrogen and Diatomic Molecular AlO, C2, CN, and TiO Spectra Following Laser-induced Optical Breakdown
Published on: February 14, 2014
14.3K
08:22Measurement of Ultrafast Vibrational Coherences in Polyatomic Radical Cations with Strong-Field Adiabatic Ionization
Published on: August 6, 2018
7.0K
相关概念视频
UV–Vis Spectrometers
1.5K
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell.
1.5K
Deactivation Processes: Jablonski Diagram
875
Luminescence, the emission of light by a substance that has absorbed energy, is a process that involves the interaction of molecules with light. The energy-level diagram, or Jablonski diagram, is a graphical representation of these interactions, illustrating the various states and transitions a molecule can undergo. In a typical Jablonski diagram, the lowest horizontal line represents the ground-state energy of the molecule, which is usually a singlet state. This state represents the energies...
875
Atomic Absorption Spectroscopy: Atomization Methods
654
Atomic Absorption Spectroscopy (AAS) atomizes samples through flame atomization or electrothermal atomization. Flame atomization typically involves a nebulizer and spray chamber assembly to combine the sample with a fuel–oxidant mixture, creating a fine aerosol mist that enters a burner. Typically, the fuel and oxidant are combined in an approximately stoichiometric ratio. However, for atoms that are easily oxidized, a fuel-rich mixture may be more advantageous. Only about 5% of the...
654
Atomic Absorption Spectroscopy: Instrumentation
940
An atomic absorption spectrophotometer (AAS) comprises several components: a radiation source, an atomizer, a monochromator, and a detector. The radiation source can be a hollow-cathode lamp (HCL) or an electrodeless-discharge lamp (EDL), both of which provide a narrow emission line of the required wavelength. However, some instruments use continuum sources and high-resolution monochromators to achieve a narrow range of radiation.
The atomizer used in AAS can be either a flame atomizer or an...
The atomizer used in AAS can be either a flame atomizer or an...
940
Flame Photometry: Overview
794
Flame photometry, also known as flame emission spectrometry, is a technique used for the qualitative and quantitative analysis of elements present in a sample using a flame as the source of excitation energy. The concept of flame photometry was realized in the early 1860s by Kirchhoff and Bunsen, who discovered that specific elements emit characteristic radiation when excited in flames. The first instrument developed for this purpose was used to measure sodium (Na) in plant ash using a Bunsen...
794
Flame Photometry: Lab
359
In a flame photometer, when a solution like potassium chloride is aspirated into the flame, the solvent evaporates, leaving behind dehydrated salt. This salt dissociates into free gaseous atoms in their ground state. Some of these atoms absorb energy from the flame, leading to their excitation. The excited atoms return to the ground state, emitting photons at characteristic wavelengths. Because only electronic transitions are involved, the resulting emission lines are very narrow. The intensity...
359