一个双向级联变压器网络用于水下窄带信号增强
Lei Zhou1,2,3, Shihong Zhou1, Yubo Qi1
1State Key Laboratory of Acoustics and Marine Information, Institute of Acoustics, Chinese Academy of Sciences, Beijing, 100190, China.
The Journal of the Acoustical Society of America
|September 4, 2025
概括
这项研究引入了一种新型的双向级变压器网络 (BCT-Net),用于增强水下窄带声信号. 该网络能够有效地检测和消除微弱的船舶噪声,即使信号与噪声的比率非常低.
科学领域:
- 水下声学
- 信号处理
- 声学中的深度学习
背景情况:
- 船舶噪声的窄频组件对于目标检测至关重要.
- 水下环境会降低声信号质量,特别是在信号与噪声比较低的情况下.
- 有限的深度学习研究存在于水下窄带信号消噪.
研究的目的:
- 介绍一个新的深度学习模型,用于水下窄带声信号增强.
- 提高在具有挑战性的声条件下对船舶目标的检测和识别.
- 在低信号噪声比环境中解决传统方法的局限性.
主要方法:
- 开发了一种双向级变压器网络 (BCT-Net),具有双重特征提取分支.
- 使用级联注意力机制来增强窄带特征检测.
- 集成的频率引导注意力和双向交叉注意力,用于优越的特征提取和噪音抑制.
主要成果:
- 在低至-20dB的信号噪声比率下,BCT-Net能够成功检测到窄带特征.
- 该模型通过目标和噪声分支之间的特征相互作用来证明优异的噪声抑制.
- 实现了微妙的频率变化和有效的信号分离的细粒度重建.
结论:
- 拟议的BCT-Net显著提高了在水下声学中的窄带信号消噪性能.
- 在BCT-Net中的每个模块都有其独特的贡献,以提高其消除噪音的能力.
- 在窄带信号增强方面,BCT-Net的性能优于现有的方法,证明了它的有效性.
更多相关视频
05:11High-precision Electromagnetic Flowmeter with Empty Pipe Detection via Complex Programmable Logic Device-based Waveform Recognition
Published on: June 27, 2025
205
09:36Continuous-Wave Propagation Channel-Sounding Measurement System - Testing, Verification, and Measurements
Published on: June 25, 2021
3.2K
相关概念视频
Cascaded Op Amps
714
Operational amplifiers (op-amps) are versatile electronic components that can be interconnected in a cascade - one after another in a linear sequence. This cascading is possible due to their infinite input resistance and zero output resistance, allowing them to maintain their input-output relationships even when connected in series.
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
In a cascaded system, each op-amp is referred to as a stage. The output of one stage drives the input of the subsequent stage. As the input signal passes through...
714
Reducing Line Loss
193
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss...
193
Equivalent Circuits for Practical Transformers
784
The practical equivalent circuits of single-phase two-winding transformers exhibit significant deviations from their idealized versions due to the inherent properties of winding resistance and finite core permeability. These properties result in real and reactive power losses, affecting the transformer's performance. Understanding these deviations is crucial for designing more efficient transformers.
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
In a practical transformer, each winding exhibits resistance and leakage reactance. The...
784
Three-Winding Transformers
305
Three identical single-phase transformers can be configured to form a three-phase transformer connection, which involves high-voltage and low-voltage windings. The high-voltage windings are denoted by capital letters A-B-C, while the low-voltage windings are labeled with lowercase letters a-b-c, representing their respective phases. This notation helps distinguish between the high and low voltage sides of the transformer.
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
In the per-unit equivalent circuit of a grounded Y-Y three-phase...
305
Transmission Line Design Considerations
213
Aluminum has become the material of choice for overhead transmission lines, surpassing copper due to its abundance and cost-effectiveness. The most prevalent type is the aluminum conductor, steel-reinforced (ACSR), which combines aluminum strands around a steel core. Other variants include all-aluminum conductors (AAC), all-aluminum alloy conductors (AAAC), aluminum conductor alloy-reinforced (ACAR), and aluminum-clad steel conductors. Advanced designs, such as aluminum conductors with steel...
213
Directional Relays
188
Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
188