混合断和全换之间的早期和中期结果的比较:倾向匹配研究的系统审查和元分析
Naritsaret Kaewboonlert1, Worawong Slisatkorn2, Apichat Tantraworasin3
1School of Surgery, Institute of Medicine, Suranaree University of Technology, Nakhon Ratchasima, Bangkok, Thailand.
PloS one
|September 4, 2025
概括
混合门修复 (HAR) 和全门置换 (TAR) 显示出对大动脉门病理的住院死亡率相似. 在特定的患者群体中,HAR降低了功能衰竭的风险,而ART则降低了再干预率.
科学领域:
- 心血管外科
- 胸腔大动脉手术
- 医疗技术评估
背景情况:
- 大动脉门病理需要复杂的手术修复,混合门修复 (HAR) 和全门置换 (TAR) 是关键策略.
- 哈尔与TAR的比较有效性仍然是一个活跃的研究领域,特别是在早期和中期结果方面.
- 通过尽量减少混因素,倾向性得分匹配的研究提供了对治疗效果的宝贵见解.
研究的目的:
- 系统地审查与混合门修复 (HAR) 和全门置换 (TAR) 匹配的倾向性研究.
- 总结和比较大动脉病理的HAR和TAR之间的早期和中期结果.
- 确定两种手术方法之间的特定并发症和再干预率的潜在差异.
主要方法:
- 在PubMed,Embase,Cochrane图书馆和谷歌学者中进行系统的文献搜索至2024年4月.
- 包括对HAR和TAR进行比较的倾向分数匹配研究.
- 对住院死亡率 (概率比) 和时间到事件结果 (危险比) 的元分析.
主要成果:
- 在HAR和TAR之间的住院死亡率没有显著差异 (OR0. 66; p=0. 240).
- 脏衰竭的发生率显著降低 (OR0. 51; p=0. 020).
- 在混合退行解剖 (MDAD) 中,ART的三年复发率显著降低 (HR 2. 99; p< 0. 001).
结论:
- 混合门修复与完全门置换相比,在减少功能衰竭方面具有好处.
- 整体门置换可能有助于降低特定混合退化切割大动脉病理的再干预率.
- 研究结果表明,根据患者子组和预期的结果,在HAR和TAR之间进行细微选择,因此需要进一步调查.
相关概念视频
¹H NMR: Complex Splitting
1.7K
A proton M that is coupled to a proton X results in doublet signals for M. However, NMR-active nuclei can be simultaneously coupled to more than one nonequivalent nucleus. When M is coupled to a second proton A, such as in styrene oxide, each peak in the doublet is split into another doublet.
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
Splitting diagrams or splitting tree diagrams are routinely used to depict such complex couplings. While drawing splitting diagrams, the splitting with the larger coupling constant is usually applied...
1.7K
Expected Frequencies in Goodness-of-Fit Tests
7.0K
A goodness-of-fit test is conducted to determine whether the observed frequency values are statistically similar to the frequencies expected for the dataset. Suppose the expected frequencies for a dataset are equal such as when predicting the frequency of any number appearing when casting a die. In that case, the expected frequency is the ratio of the total number of observations (n) to the number of categories (k).
7.0K
Multiple Comparison Tests
3.5K
Multiple comparison test, abbreviated as MCT, is a post hoc analysis generally performed after comparing multiple samples with one or more tests. An MCT will help identify a significantly different sample among multiple samples or a factor among multiple factors.
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
3.5K
Effects of EDTA on End-Point Detection Methods
829
Different methods, such as visual observance of metal-ion indicators, spectroscopic techniques, and potentiometric methods, can determine the endpoint of an EDTA titration.
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
829
Mass Spectrometry: Complex Analysis
2.1K
Mass spectrometry is an important technique for the identification of pure compounds. However, it has some limitations for the analysis of complex mixtures, often due to excessive fragmentation making the spectrum too complicated to decipher. Mass spectrometry can be combined with suitable separation methods in sequence, forming hyphenated methods, which are useful in the analysis of complex mixtures.
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
2.1K
Tandem Mass Spectrometry
3.0K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
3.0K