听力助听器使用者的现实听力体验与现场心率和声学数据有关
Klaudia Edinger Andersson1,2, Jeppe Høy Christensen3, Rasmus P Skipper4
1Department of Clinical Research, University of Southern Denmark, Odense.
Journal of speech, language, and hearing research : JSLHR
|September 4, 2025
概括
大声和噪音环境会使助听器用户的听力体验恶化,尤其是在专注听力时. 声学条件和倾听意图显著影响现实世界的声音感知.
科学领域:
- 听力学
- 听力学
- 人与计算机的交互
背景情况:
- 生态瞬间评估 (EMA) 和声学数据记录提供了对助听器 (HA) 用户体验的见解.
- 之前对正常听力个体的研究将较高的声压水平 (SPL) 和较低的信号噪声比 (SNR) 与较差的听力评级联系起来.
- 倾听的意图会影响生理反应, 倾听时心率会更高, 听力会更好.
研究的目的:
- 调查助听器使用者的真实听力体验.
- 确定环境声学 (SPL,SNR) 和听力意图是否会影响HA用户的体验.
- 探索心率,倾听意图和感知声音环境之间的关系.
主要方法:
- 16名经验丰富的HA使用者参与了一项为期2周的基于智能手机的EMA研究.
- 参与者报告了一般的听力体验和感知到的噪音,以及听力意图 (以语音为重点,以他人为重点,不以语音为重点).
- 测试HAs在现场记录了SPL和SNR,而腕带收集了连续心率数据.
主要成果:
- 较差的听力体验与更高的SPL,更低的SNR和更高的心率相关.
- 较高的感知噪声与较高的SPL和较低的SNR有关.
- 与非集中式倾听相比,在集中式倾听 (语音或其他集中式) 中降低SNR显著恶化了听力体验和感知噪音.
结论:
- 环境声音压力和噪音的升高会对高频用户的听力体验产生负面影响.
- 专注的听力,特别是对语音或其他声音,对声学条件降低 (较低的SNR) 特别敏感.
- 环境声学和使用者的倾听意图是影响助听器使用效率和体验的关键因素.
更多相关视频
06:58An Application for Pairing with Wearable Devices to Monitor Personal Health Status
Published on: February 3, 2022
2.9K
11:39Assessment of Audio-Tactile Sensory Substitution Training in Participants with Profound Deafness Using the Event-Related Potential Technique
Published on: September 7, 2022
2.2K
相关概念视频
Heart Sounds
2.3K
Heart sounds are generated by the turbulence in blood flow due to the closing of heart valves. These sounds are best perceived slightly away from the valves, where the blood flow disseminates the sound.
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
Auscultation is the process of listening to these internal body sounds using a stethoscope. The heart produces four types of sounds, but only two—S1 and S2—can usually be heard with a stethoscope.
S1, also known as the "lub" sound, is caused by the closure of atrioventricular (A-V)...
2.3K
Equipments Used To Measure Blood Pressure
1.7K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
1.7K
Pulse rhythm
924
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
924
Assessment of the Cardiovascular System IV: Auscultation
642
Cardiac auscultation is a clinical skill used to assess heart function and detect abnormalities. It involves listening to heart sounds at specific anatomical locations through a stethoscope.
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
Normal Heart Sounds
S1 (First Heart Sound)-
S1 is made by the closure of the mitral and tricuspid valves (atrioventricular valves), marking the beginning of systole.
S2 (Second Heart Sound)-
S2 is made by the closure of the aortic and pulmonic valves (semilunar valves), marking the end of the systole.
642
