了解唾液化物水平的变化:基于试验数据的二次轨迹分析
Line Staun Larsen1, Vibeke Baelum1, Eero Juhani Raittio1,2
1Department of Dentistry and Oral Health, Aarhus University, Aarhus, Denmark.
European journal of oral sciences
|September 5, 2025
概括
高化物牙膏 (5000 ppm) 显示出比标准 (1450 ppm) 的唾液化物更大的可变性. 个体反应有所不同,突出显示在临床试验中需要重复测量.
科学领域:
- 牙科研究
- 化物毒理学
- 生物标志物分析
背景情况:
- 化牙膏的有效性已被证实.
- 不同人群的最佳化物度仍在研究中.
- 唾液化物水平的个体变化尚未完全理解.
研究的目的:
- 分析唾液化物水平的时间变化和纵向轨迹.
- 为了比较唾液化物反应,使用的化物牙膏含量为5000ppm和1450ppm.
- 在试验和洗阶段调查个体参与者的反应.
主要方法:
- 随机对照试验 (RCT) 数据的二次分析.
- 在3周使用5000ppm与1450ppm牙膏时,唾液中化物水平的比较.
- 所有参与者使用1450ppm牙膏进行为期2周的洗阶段 (n=48).
主要成果:
- 与1450ppm相比,使用5000ppm的牙膏观察到唾液化物水平的更高变化.
- 在参与者身上发现了三个不同的唾液化物轨迹 (低,中,高).
- 在洗过程中"高"的唾液化物集群仅包括来自5000ppm组的参与者.
结论:
- 对高剂量 (5000ppm) 牙膏的唾液化物反应是不稳定的,并显示个体的变化.
- 建议进行重复期交叉试验,以评估治疗效果的异质性.
- 需要进一步的研究来了解和减少唾液化物水平的个体变化来源.
相关概念视频
Titration of Polyprotic Base with a Strong Acid
4.7K
The titration of a polyprotic base such as sodium carbonate with a strong acid such as hydrochloric acid results in two equivalence points on the titration curve. At the first equivalence point, the carbonate ions in the base are completely converted to bicarbonate ions. The second equivalence point corresponds to the complete conversion of bicarbonate ions to carbonic acid, which dissociates into carbon dioxide and water. The region before the first equivalence point corresponds to the...
4.7K
Analyte Adsorption and Distribution
2.8K
In certain chromatographic separations, solutes transfer between the mobile phase and the stationary phase via sorption, which typically refers to the process of adsorption. For many chromatographic systems, the sorption process often depends on the polarity of the compounds—an expression of the overall dipole moment within the molecule. During the separation process, there is competition between the solute and solvent for adsorption to the stationary phase. Highly polar compounds and...
2.8K
Nonideal Two-Component Liquid Solutions
137
Nonideal liquid solutions, also known as real solutions, do not strictly follow Raoult's law. Raoult's law is a rule of thumb in physical chemistry. However, not all mixtures adhere to this law due to varying molecular interactions. For example, in an acetone/chloroform solution, the individual vapor pressures of the components are lower than expected, resulting in a total vapor pressure below that predicted by Raoult's law, causing a negative deviation.On the other hand, in an ethanol/water...
137
Transport Number
230
The transport number is the fraction of the total current carried by an ion in an electrolyte solution. It is defined as the ratio of the current carried by a specific ion to the total current flowing through the solution. The transport number, t, is central to understanding ionic mobility, which describes how fast an ion moves under the influence of an electric field. This link connects the physical behavior of ions in solution to the chemical processes that occur during electrochemical...
230
Drug Dissolution: Requirements and Profile Comparison
500
The acceptance criteria for dissolution profile data are anchored in Q values, representing the percentage of drug dissolved within a specified period. This assessment unfolds in three stages:First Stage: The test passes if all six drug dosage units are equal to or greater than Q plus 5%; otherwise, the sample proceeds to the second stage.Second Stage: The average of twelve units must be equal to or greater than Q, with no unit falling below Q - 15% to pass; if not, it progresses to the final...
500