Atomic Absorption Spectroscopy: Lab01:21

Atomic Absorption Spectroscopy: Lab

551
For AAS measurements, samples must be introduced as clear solutions, often requiring extensive preliminary treatment to dissolve materials like soils, animal tissues, and minerals. Common methods for sample preparation include treatment with hot mineral acids, wet ashing, combustion in closed containers, high-temperature ashing, or fusion with reagents.
 Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
551

您也可能阅读

相关文章

通过共同作者、期刊和引用图与本文相关的文章。

排序
Same author

Uncertainty and covariance matrix of the coincidence-summing correction factors due to decay-data uncertainties.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2023
Same author

On homogeneity approximation in calibration of gamma-spectrometry assessment of bulk samples.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2017
Same author

Monte Carlo simulation of air sampling methods for the measurement of radon decay products.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2017
Same author

Efficiency computation for gamma-ray spectrometry assessment of samples with intrinsic inhomogeneity.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2017
Same author

Application of GUM Supplement 1 to uncertainty of Monte Carlo computed efficiency in gamma-ray spectrometry.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2016
Same author

Distribution of the ²²²Rn decay products from a ²²⁶Ra solution in a PTB ampoule--implications for calibration.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine·2013

相关实验视频

Updated: Sep 8, 2025

Assembly and Characterization of Polyelectrolyte Complex Micelles
08:44

Assembly and Characterization of Polyelectrolyte Complex Micelles

Published on: March 2, 2020

10.9K

在体积样本中的Pb-210:自我减弱和散射问题

Octavian Sima1, Daniela Gurau2

  • 1Physics Department, University of Bucharest, 405 Atomistilor Str., PO Box MG-12, Magurele, Ilfov County, RO-077125, Romania; Horia Hulubei National Institute for R&D in Physics and Nuclear Engineering (IFIN-HH), 30 Reactorului Str., PO Box MG-6, Magurele, Ilfov County, RO-077125, Romania.

Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine
|September 6, 2025
PubMed
概括
此摘要是机器生成的。

源矩阵效应影响低能光子谱和峰值效率. 切实可行的模拟显示了康普顿散射对峰值率的影响,但可以对准确的线性衰减系数 (μ) 确定和自我衰减计算进行校正.

关键词:
(210) Pb 在其他国家马光谱学矩阵效应蒙特卡洛模拟皮内洛普自动减弱传输方式

更多相关视频

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
08:53

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level

Published on: June 6, 2018

8.1K
Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
11:27

Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2

Published on: December 8, 2016

12.4K

相关实验视频

Last Updated: Sep 8, 2025

Assembly and Characterization of Polyelectrolyte Complex Micelles
08:44

Assembly and Characterization of Polyelectrolyte Complex Micelles

Published on: March 2, 2020

10.9K
Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
08:53

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level

Published on: June 6, 2018

8.1K
Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2
11:27

Studying Soft-matter and Biological Systems over a Wide Length-scale from Nanometer and Micrometer Sizes at the Small-angle Neutron Diffractometer KWS-2

Published on: December 8, 2016

12.4K

科学领域:

  • 核物理和仪器仪表
  • 光子检测和光谱学
  • 辐射屏蔽和减弱

背景情况:

  • 源矩阵的组成显著影响辐射检测测量.
  • 精确的低能光子表征对于各种应用至关重要.
  • 康普顿散射可能会使光谱分析和效率的确定变得复杂.

研究的目的:

  • 研究源矩阵材料对光子光谱和完全能量峰值效率的影响.
  • 要量化康普顿散射对峰值计数率的贡献.
  • 开发一种纠正矩阵效应并确定线性衰减系数 (μ) 的方法.

主要方法:

  • 使用PENELOPE 2018进行现实的模拟,并结合探测器分辨率.
  • 分析光谱数据以识别和分离康普顿散射贡献.
  • 用于评估线性衰减系数 (μ) 的非聚合传输测量.

主要成果:

  • 发现小角度的康普顿散射有助于峰值计数率.
  • 矩阵效应取决于线性衰减系数 (μ) 和散射截面.
  • 开发了一种方法来消除康普顿散射效应,产生完全依赖于μ的"清洁"峰值.
  • 该程序成功地用于确定μ并计算自我减弱校正.

结论:

  • 对于精确的低能光子测量,必须考虑源矩阵效应,特别是康普顿散射.
  • 开发的方法提供了一种可靠的方法来确定线性衰减系数 (μ) 和正确的自我衰减.
  • 这项工作有助于提高通过相互比较测量验证的辐射检测和特征的准确性.