嵌套静电线性离子陷的演示,以灵活选择分析仪的优点数据
Jordan M Fritz1, Ian J Carrick1, Nicholas R Ellin1
1Department of Chemistry, Purdue University, 560 Oval Drive, West Lafayette, IN 47907-2084, USA.
概括
一个新的嵌套静电线性离子陷 (NELIT) 为质谱学提供可调长度,平衡质量范围和分辨能力. 这种设计增强了离子分析,允许在一个设备内在两个陷长度之间进行选择.
科学领域:
- 分析化学 分析化学
- 质谱测量质量谱测量
- 仪器化 仪器化 仪器化
背景情况:
- 静电线性离子陷 (ELIT) 根据使用频率分析的质量电荷比 (m/z) 分离离子.
- 一个ELIT的长度会影响m/z范围和分辨能力之间的权衡.
- 优化ELIT设计对于先进的质谱应用至关重要.
研究的目的:
- 为灵活的离子陷长度选择引入嵌套ELIT (NELIT) 设计.
- 调查NELIT几何学对m/z范围和分辨能力的影响.
- 展示一种新的方法来提高离子陷分析仪的性能.
主要方法:
- 使用单个检测电极实现一个嵌套的ELIT (NELIT),具有两个可选择的陷长度.
- 利用时间域信号的里叶变换 (FT) 进行频谱分析.
- 描述NELIT中的两个陷之间的有效长度比.
主要成果:
- NELIT 设计允许在单个装置内切换两个 ELIT 长度.
- 在NELIT中,两个陷的有效长度比为2.40.
- 这种配置提供了一种调整 m/z 范围和解决功率权衡的方法.
结论:
- NELIT为质谱学提供了一种多功能解决方案,克服了固定长度ELIT固有的局限性.
- 这种可适应的离子陷设计为更广泛的分析挑战提供了更好的性能.
- 该NELIT代表了离子陷仪器仪表的重大进步.
相关概念视频
Mass Analyzers: Common Types
1.4K
The quadrupole mass analyzer consists of four cylindrical metal rods arranged in a diamond carrying a DC voltage and a radio-frequency AC voltage. The motion of ions through the quadrupole depends on the field strength, causing only ions of a certain m/z to resonate successfully and strike the detector at a given field strength. Though the transmission rate for these analyzers is high, the exact elemental composition of the sample is not determined because of low resolution; however, they are...
1.4K
Mass Analyzers: Overview
1.6K
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
1.6K
Tandem Mass Spectrometry
2.3K
Tandem mass spectrometry is a technique that uses multiple mass analyzers in series to obtain a higher selectivity and reduce chemical noise during analyte detection. Instruments with multiple analyzers separated by an interaction cell enable secondary fragmentation and selected study of the fragment ions.Secondary fragmentations occur in the interaction cell and can be induced by various factors. Fragmentation induced by collision with inert gases, such as N2, Ar, He, etc., is called...
2.3K
Mass Spectrometers
8.3K
This lesson details the instrumentation of a mass spectrometer—a physical instrument to perform mass spectrometry on analyte molecules and record the characteristic mass spectra. This is achieved via three chief functions:
8.3K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
667
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
667
Electrospray Ionization (ESI) Mass Spectrometry
2.1K
Higher molecular weight biomolecules are nonvolatile compounds that may decompose before ionizing or vaporizing during mass analysis with conventional electron impact ionization methods. Accordingly, electrospray ionization (ESI) is the favored method for vaporizing and ionizing biomolecules as it circumvents rapid fragmentation and enables the recording of mass signals for the entire biomolecule.
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
2.1K