对各种恶性瘤中PET/CT图像重建的Ordered Subset Expectation Maximization和贝叶斯惩罚性概率算法的比较评估,使用F-FDG和68Ga-PSMA-11追踪器
Arvin Naeimi1,2, Sara Harsini3, Ramin Akbarian Aghdam4
1Department of Radiology, McGill University Health Center, McGill University, Montreal, QC, Canada.
Frontiers in oncology
|September 15, 2025
概括
贝叶斯惩罚概率 (BPL) 和有序子集预期最大化 (OSEM) PET/CT重建算法显示出临床效用. 虽然BPL产生了更高的定量指标,但存在显著的变化,这表明在没有协调的情况下谨慎进行纵向研究.
科学领域:
- 核医学是一种核医学.
- 医学成像医学成像
- 放射化学 放射化学是指辐射化学.
背景情况:
- 阳离子辐射断层扫描/计算机断层扫描 (PET/CT) 对于癌症诊断和监测至关重要.
- 像OSEM和BPL (Q.Clear) 这样的图像重建算法会影响定量准确性.
- 标准化摄入值 (SUV) 和瘤与背景比率 (TBR) 是关键指标.
研究的目的:
- 为了比较OSEM和BPL算法的性能,用于PET/CT图像重建.
- 评估这些算法对使用18F-FDG和68Ga-PSMA-11追踪器的定量指标的影响.
主要方法:
- 对33名患者 (25名FDG,8名PSMA) 的回顾性分析.
- 使用OSEM和BPL算法重建的PET/CT扫描.
- 评估包括SUVmax,SUVpeak,背景SUV和TBR在内的定量指标.
主要成果:
- 在FDG和PSMA组中,与OSEM相比,BPL通常产生更高的定量值 (SUVpeak,TBR).
- 在BPL和OSEM指标之间观察到强烈的线性相关性 (r>0.85).
- 布兰德-阿尔特曼分析揭示了广泛的共识范围,特别是PSMA成像中的TBR,这表明存在相当大的变化.
结论:
- OSEM和BPL算法都在临床上有用,BPL增强了一些定量指标,但没有显著改善病变检测.
- 由于观察到的可变性,BPL和OSEM的直接可互换性是有限的,特别是在纵向研究中.
- 建议采用协调策略和一致使用重建方法,以便在多中心或纵向环境中可靠量化.
关键词:
BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL BPL贝叶斯主义者惩罚了概率.这就是OSEMEM OSEM.订制子集预期最大化最大化聚乙烯/聚乙烯/聚乙烯positron发射断层扫描-计算机断层扫描图像重建 图像重建标准化吸收值是标准化的吸收值.更多相关视频
06:53Management of Respiratory Motion Artefacts in 18F-fluorodeoxyglucose Positron Emission Tomography using an Amplitude-Based Optimal Respiratory Gating Algorithm
Published on: July 23, 2020
6.1K
10:28Gene Regulation and Targeted Therapy in Gastric Cancer Peritoneal Metastasis: Radiological Findings from Dual Energy CT and PET/CT
Published on: January 22, 2018
11.5K
相关概念视频
Positron Emission Tomography
7.0K
Positron emission tomography (PET) is a medical imaging technique involving radiopharmaceuticals — substances that emit short-lived radiation. Although the first PET scanner was introduced in 1961, it took 15 more years before radiopharmaceuticals were combined with the technique and revolutionized its potential.
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
7.0K
Imaging Studies II: Positron Emission Tomography and Scintigraphy
505
Positron Emission Tomography (PET) is a medical imaging technique that provides crucial insights into the body's physiological functions at a molecular level. It is an indispensable resource for diagnosing, staging, and monitoring various illnesses, notably cancer, neurological disorders, and cardiovascular conditions.
Fundamental Principles of PET
Fundamental Principles of PET
505