基站设备缺陷检测基于改进的YOLOv8
Yiwei Sun1, Xiangran Sun2, Ying Lin1
1State Grid Shandong Electric Power Research Institute, Jinan 250003, China.
Sensors (Basel, Switzerland)
|September 19, 2025
概括
这项研究使用改进的YOLOv8对象检测算法来增强变电站设备缺陷检测. 优化的模型实现了更高的准确性,确保了可靠的动力系统运行.
科学领域:
- 电气工程 电气工程
- 计算机视觉 计算机视觉
- 人工智能的人工智能
背景情况:
- 变电站设备缺陷对电力系统稳定性构成风险.
- 准确而高效的缺陷检测对于预防性维护至关重要.
研究的目的:
- 开发一个增强的对象检测算法用于变电站设备缺陷.
- 为了提高YOLOv8模型对于这个特定应用的性能.
主要方法:
- 用EfficientViT替换了YOLOv8骨干,以获得更好的特征提取.
- 集成的挤压和刺激 (SE) 注意力机制,用于增强特征表示.
- 用FasterBlock替换了瓶组件,以加快推断速度.
主要成果:
- 在缺陷检测数据集上实现了92.8%的平均平均精度 (mAP).
- 与基线YOLOv8模型相比,mAP表现出1.8%的改善.
- 验证了EfficientViT,SE注意力和FasterBlock修改的有效性.
结论:
- 拟议的修改显著增强YOLOv8用于变电站设备缺陷检测.
- 改进的算法为保持电力系统可靠性提供了可行和有效的解决方案.
- 优化的模型平衡了准确性和推断速度,以实现实际部署.
相关概念视频
Detection of Gross Error: The Q Test
6.9K
When one or more data points appear far from the rest of the data, there is a need to determine whether they are outliers and whether they should be eliminated from the data set to ensure an accurate representation of the measured value. In many cases, outliers arise from gross errors (or human errors) and do not accurately reflect the underlying phenomenon. In some cases, however, these apparent outliers reflect true phenomenological differences. In these cases, we can use statistical methods...
6.9K
Types of Errors: Detection and Minimization
10.2K
Error is the deviation of the obtained result from the true, expected value or the estimated central value. Errors are expressed in absolute or relative terms.
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
10.2K
Lumber Defects
476
Lumber defects, which can affect both the appearance and structural integrity of wood, include a variety of growth and manufacturing flaws. Growth defects such as knots and knotholes occur where branches were once attached to the tree trunk, with knotholes forming when these knots fall out. Other natural defects include decay and insect damage, which compromise the wood's strength and durability.
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
Shakes are minor fractures that run along or across the wood's annual rings, while wane is...
476
Lossy Lines and Overvoltages
353
Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
353
Reducing Line Loss
366
In a three-phase circuit, line loss is an indicator of energy dissipated as heat due to the resistance of transmission lines. To address this, incorporating transformers into the system—a step-up transformer at the source and a step-down transformer at the load—is a strategic solution. Two three-phase transformers are introduced to improve this.
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
366
Leaky Scanning
5.6K
During most eukaryotic translation processes, the small 40S ribosome subunit scans an mRNA from its 5' end until it encounters the first start AUG codon. The large 60S ribosomal subunit then joins the smaller one to initiate protein synthesis. The location of the translation initiation is largely determined by the nucleotides near the start codon as there may be multiple translation initiation sites present on the mRNA. Marilyn Kozak discovered that the sequence RCCAUGG (where R...
5.6K