用模糊和FAHP模型进行基于部分放电的电缆漏洞排名:在丹麦分发网络中的应用
Mohammad Reza Shadi1, Hamid Mirshekali1, Hamid Reza Shaker1
1SDU Center for Energy Informatics, Maersk Mc-Kinney Moeller Institute, The Faculty of Engineering, University of Southern Denmark, 5230 Odense, Denmark.
Sensors (Basel, Switzerland)
|September 19, 2025
概括
本研究引入了一种新的方法,用于使用模糊逻辑和模糊分析层次过程 (FAHP) 优先考虑地下电缆更换. 它结合了电缆年龄和部分放电 (PD) 数据,以更准确的基于条件的评估.
科学领域:
- 电气工程 电气工程
- 电力系统分析 分析 分析
- 资产管理资产管理.
背景情况:
- 地下电缆的老化对发电系统构成重大风险.
- 目前基于年龄的替换策略不足以评估实际的电缆状况.
- 部分排放 (PDs) 是绝缘降解的关键早期指标.
研究的目的:
- 开发一个强大的框架,根据条件对地下电缆漏洞进行排名.
- 管理电缆年龄和PD数据的不确定性,以改进维护决策.
- 提供一个具有成本效益的,数据驱动的方法来优先考虑电缆更换.
主要方法:
- 模糊逻辑和模糊分析层次过程 (FAHP) 框架的实施.
- 基本数据的整合:电缆年龄和部分放电 (PD) 测量 (峰值,事件计数).
- 使用蒙特卡洛模拟,斯皮尔曼相关性分析和现实世界的操作数据进行验证.
主要成果:
- 拟议的基于FAHP的框架实际上将电缆脆弱性列为不确定性.
- 该方法提供了强大的和一致的结果,改进了传统的基于年龄的策略.
- 使用来自丹麦分销网络和合成PD数据的数据证明了有效性.
结论:
- FAHP框架为基于条件的电缆维护优先级提供了一个可靠的解决方案.
- 这种方法支持公用事业公司在资产管理方面做出更明智,更经济的决策.
- 该研究强调了将PD数据与电缆年龄相结合的重要性,以准确评估脆弱性.
相关概念视频
Cable Subjected to a Distributed Load
1.1K
The analysis of suspension bridges is a complex and critical process that involves multiple factors, including the shape and tension of the main cables. The main cables of suspension bridges are subjected to distributed loads, which result in changes in tensile forces and deformation of the cable. These loads must be carefully considered to ensure that the bridge is safe and capable of supporting the weight of different loads.
1.1K
Distribution Reliability and Automation
497
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
497
Reclosers and Fuses
454
Automatic circuit reclosers enhance the protection of distribution circuits by interrupting and auto-reclosing an AC circuit according to a preset sequence. They effectively manage temporary faults on overhead distribution lines, often caused by tree limbs or wildlife, by briefly disrupting service to improve overall reliability. However, contact with reclosers or energized broken conductors on the ground can pose serious hazards.
A comprehensive protection scheme for radial distribution...
A comprehensive protection scheme for radial distribution...
454
Primary Distribution
531
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
531
Secondary Distribution
555
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
555
Cable Subjected to Concentrated Loads
1.4K
Flexible cables are commonly used in various applications for support and load transmission. Consider a cable fixed at two points and subjected to multiple vertically concentrated loads. Determine the shape of the cable and the tension in each portion of the cable, given the horizontal distances between the loads and supports.
1.4K