一个近场无线电频率系统,用于连续的左和右肺体积传感
Aakash Kapoor1, Thomas B Conroy1, Kapil Gangwar1
1Department of Electrical and Computer Engineering, Cornell University, Ithaca, NY 14853, USA.
概括
近场无线电频率 (NFRF) 传感器提供了一种新的,非侵入性的方法,用于连续的,个别的肺体积监测. 这种可穿戴技术有助于管理呼吸困难,并检测诸如肺胸炎之类的危急情况.
科学领域:
- 生物医学工程 生物医学工程
- 呼吸系统生理学 呼吸系统生理学
- 可穿戴技术可穿戴技术
背景情况:
- 肺功能测试对于诊断呼吸系统疾病至关重要.
- 目前的方法往往需要临床设置,限制在家监测.
- 为方便的呼吸健康跟踪,人们寻求非侵入性技术.
研究的目的:
- 评估近场无线电频率 (NFRF) 传感器,用于连续,独立的肺体积监测.
- 为了评估NFRF传感器与传统螺旋计的准确性.
- 证明监测个体肺动态的能力.
主要方法:
- 在机械通风的猪模型上应用了NFRF传感器.
- 在干预期间,传感器测量了肺动力学和潮体积.
- 支气管阻断剂隔离每一个肺部进行独立监测;螺旋计作为参考.
主要成果:
- 与螺旋计相比,NFRF传感器实现了肺体积测量,平均误差为9.2%.
- 成功监测了个体的肺动态,包括在一个肺阻塞期间.
- 证明了每一个肺独立地持续获取肺动态.
结论:
- NFRF传感器代表了一种用于持续个人肺体积监测的新型可穿戴方法.
- 这项技术可以帮助管理急性和慢性呼吸困境.
- 潜在的早期检测危及生命的条件,如肺胸部.
相关概念视频
Respiratory Volumes
2.8K
Respiratory volumes are crucial metrics, meticulously measured to quantify the air exchanged in and out of the lungs during various phases of the breathing cycle. These precise measurements are vital for assessing lung function, diagnosing respiratory conditions, and monitoring overall respiratory health. Each parameter provides specific insights into the mechanics of breathing and the functional capacity of the lungs.
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
2.8K
Respiratory Volumes and Capacities
4.9K
The respiratory system is responsible for the intake of oxygen and the expulsion of carbon dioxide from the body. Respiratory volumes describe the volume of air in the lungs at different phases of the respiratory cycle. Tidal volume is the air breathed in and out during normal, quiet breathing. Inspiratory reserve volume is the air that can be forcefully inspired beyond the tidal volume. In contrast, expiratory reserve volume refers to the air that can be expelled from the lungs after a normal...
4.9K
Respiratory Volumes and Capacities I
1.6K
Assessing the respiratory rate and rhythm for a complete minute is crucial for evaluating the breathing pattern. Even a minor increase in the patient's average respiratory rate, by as little as three to five breaths per minute, is an early and vital indicator of respiratory distress. Patients with a respiratory rate exceeding twenty-four breaths per minute require close monitoring to determine the physiological alterations. This careful observation is essential for prompt recognition and...
1.6K
Respiratory System Abnormal Finding II: Palpation and Auscultation
1.4K
In assessing respiratory abnormalities, palpation and auscultation are critical tools for detecting and interpreting various pathophysiological changes. These techniques provide insight into underlying disorders by evaluating tactile sensations and sounds produced by the respiratory system.
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
Palpation Findings
During a respiratory assessment, palpation can reveal several vital abnormalities:
1.4K