多级振动控制机制和粘性阻尼器与过载保护器的实验有效性
Shiming Zhang1, Yuan Wu2, Kai Yang3
1Department of Disaster Mitigation for Structures, Tongji University; zhangshimingtj@163.com.
Journal of visualized experiments : JoVE
|September 22, 2025
概括
这项研究引入了一种新的混合地震隔离系统,配有带有过载保护 (VD-OP) 的粘性阻尼器. 这种创新系统通过控制力量和提高对抗地震的结构弹性来提高地震性能.
科学领域:
- 结构工程 结构工程
- 地震工程的工程是地震工程.
- 机械工程 机械工程
背景情况:
- 传统的地震隔离系统在强烈的地震事件期间面临管理过度减压力的局限性.
- 开发先进的隔离系统对于提高结构的抗震能力至关重要.
研究的目的:
- 介绍一个创新的混合地震隔离系统,集成粘性阻尼器与过载保护 (VD-OP).
- 评估VD-OP系统在提高地震性能和克服传统方法的局限性的有效性.
主要方法:
- 用实验数据校准VD-OP的机械模型的开发.
- 数字模拟和实验验证以评估系统性能.
- 在各种地震场景下进行参数研究和案例分析.
主要成果:
- VD-OP的力量限制功能显著减少了对隔离层的过度力量.
- 该系统展示了更好的隔离效率和对超结构加速反应的有效控制.
- 该VD-OP系统表现出强大的能量消耗能力和适应能力在不同的地震强度.
结论:
- VD-OP系统为提高工程结构的抗震能力提供了可靠的解决方案.
- 强力限制功能对于优化隔离效率和保护结构至关重要.
- 基于性能的设计方法有助于VD-OP系统的实际实施.
更多相关视频
07:28A Method for Evaluating Timeliness and Accuracy of Volitional Motor Responses to Vibrotactile Stimuli
Published on: August 2, 2016
7.6K
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
2.1K
相关概念视频
Types of Damping
7.5K
If the amount of damping in a system is gradually increased, the period and frequency start to become affected because damping opposes, and hence slows, the back and forth motion (the net force is smaller in both directions). If there is a very large amount of damping, the system does not even oscillate; instead, it slowly moves toward equilibrium. In brief, an overdamped system moves slowly towards equilibrium, whereas an underdamped system moves quickly to equilibrium but will oscillate about...
7.5K
Magnetic Damping
1.0K
Eddy currents can produce significant drag on motion, called magnetic damping. For instance, when a metallic pendulum bob swings between the poles of a strong magnet, significant drag acts on the bob as it enters and leaves the field, quickly damping the motion.
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
If, however, the bob is a slotted metal plate, the magnet produces a much smaller effect. When a slotted metal plate enters the field, an emf is induced by the change in flux; however, it is less effective because the slots limit the...
1.0K
Mechanical Systems
586
Mechanical systems are analogous to to electrical networks where springs and masses play similar roles to inductors and capacitors, respectively. A viscous damper in mechanical systems functions similarly to a resistor in electrical networks, dissipating energy. The forces acting on a mass in such systems include an applied force in the direction of motion, counteracted by forces from the spring, a viscous damper, and the mass's acceleration. This interplay of forces is mathematically...
586
Damped Oscillations
6.8K
In the real world, oscillations seldom follow true simple harmonic motion. A system that continues its motion indefinitely without losing its amplitude is termed undamped. However, friction of some sort usually dampens the motion, so it fades away or needs more force to continue. For example, a guitar string stops oscillating a few seconds after being plucked. Similarly, one must continually push a swing to keep a child swinging on a playground.
Although friction and other non-conservative...
Although friction and other non-conservative...
6.8K
Time-Domain Interpretation of PD Control
377
Proportional-Derivative (PD) control is a widely used control method in various engineering systems to enhance stability and performance. In a system with only proportional control, common issues include high maximum overshoot and oscillation, observed in both the error signal and its rate of change. This behavior can be divided into three distinct phases: initial overshoot, subsequent undershoot, and gradual stabilization.
Consider the example of control of motor torque. Initially, a positive...
Consider the example of control of motor torque. Initially, a positive...
377
Design Example: Underdamped Parallel RLC Circuit
630
Consider designing an oscillator circuit, a crucial component in various electronic devices and systems. The objective is to create an oscillator circuit with specific characteristics: a damped natural frequency of 4 kHz and a damping factor of 4 radians per second. To accomplish this, a parallel RLC circuit is employed, known for its ability to sustain oscillations at a resonant frequency. In this case, the damping factor is pivotal in achieving the desired performance.
Starting with a fixed...
Starting with a fixed...
630