Toshiteru Nagashima1, Yoichi Ohtaki
1Division of General Thoracic Surgery, Integrative Center of General Surgery, Gunma University, Maebashi, Japan.
Kyobu geka. The Japanese journal of thoracic surgery
|September 25, 2025
概括
一种新的微波外科设备为肺部断片切割提供了一个安全的替代方案. 这种仪器有效地密封肺组织,可能减少空气泄漏,改善胸部手术的外科结果.
科学领域:
- 胸部外科手术 胸部外科手术
- 手术创新 在外科创新.
- 最少侵入性手术的方法
背景情况:
- 肺部细分切除术越来越多地用于小型外围肺癌.
- 分段间平面剖析是关键的,但容易出现空气泄漏等并发症.
- 传统的方法包括电和合器.
研究的目的:
- 为了评估一种新的,国内开发的微波手术仪器,用于在细分切除过程中进行肺膜剖析.
- 与传统方法相比,评估本设备的安全性和有效性.
主要方法:
- 使用2450MHz的微波手术仪器封闭了肺膜.
- 该设备使用微波能量来振动水分子,在100°C以下创建凝固层.
- 这种类似剪刀的仪器用于直观而精确的剖析.
主要成果:
- 微波装置显示了最少的手术内出血.
- 在最初的经验中观察到低的术后并发症率.
- 在没有过度的热损伤的情况下实现了有效的肺膜密封.
结论:
- 微波外科设备在细分切除术中提供了一个安全有效的替代方案,用于肺膜剖析.
- 这项技术可能会改善外科手术的结果,并减少术后发病率.
- 它的精确处理和一致的密封支持其在胸部手术中的潜在采用.
相关概念视频
Molecular Spectroscopy: Absorption and Emission
Molecules possess discrete energy levels called quantum states. Unlike atoms, which have simpler energy levels, molecules possess additional rotational and vibrational energy levels. Each energy level is separated by an energy gap, with the gaps between adjacent electronic, vibrational, and rotational levels varying significantly. The three types of energy levels in a diatomic molecule are shown in Figure 1.
IR Frequency Region: X–H Stretching
In IR spectroscopy, signals produced by the X−H bonds (such as C−H, O−H, or N−H) can be observed in the frequency range of 2700–4000 cm–1. The C−H stretching vibration forms sharp bands in the region 2850–3000 cm–1. The presence of the O−H stretching vibration leads to the forming of an absorption band in the frequency range 3650–3200 cm−1. At the same time, N−H stretching can be confirmed by absorption bands in the 3500–3100 cm−1 range. Even though both O−H and N−H bonds vibrate at a similar...
Standing Waves in a Cavity
A household microwave and lasers are examples of standing electromagnetic waves in a cavity. When two conducting metal plates are placed parallel at the nodal planes, it creates a cavity where standing waves are formed. The cavity between the two planes is analogous to a stretched string held at the points x = 0 and x = L. Here, the distance 'L' between the two planes must be an integer multiple of half of the wavelength. The wavelengths that satisfy this condition are given by:
Mass Spectrum: Interpretation
An unknown compound can be established by identifying the molecular ion peak in the mass spectrum. The molecular ion peak is often weak or absent due to the predominance of fragmentation in high-energy electron beams. In such cases, a soft-energy electron beam can be used to scan the spectrum to enhance the intensity of the molecular ion peak. Additionally, chemical ionization, field ionization, and desorption ionization spectra are used to obtain a relatively intense molecular ion peak.To...
Mass Analyzers: Overview
The mass analyzer is a crucial component of the mass spectrometer. In the ionization chamber, the vaporized sample is bombarded with a high-energy electron beam to generate a radical cation and further fragment into neutral molecules, radicals, and cations. A series of negatively charged accelerator plates accelerate the cations into the mass analyzer. The mass analyzer separates ions according to their mass-to-charge (m/z) ratios and then directs them to the detector. The common types of mass...
Electronic Distance Measuring Instruments
Electronic Distance Measuring Instruments (EDMs) are essential tools in modern surveying, offering precise distance measurements by emitting electromagnetic signals and calculating the time required for these signals to travel to a target and return. Two primary types of signals are used in EDMs — light waves and microwaves — each suited to specific environmental and distance requirements. Light-wave-based EDMs utilize either infrared or laser light, providing high accuracy over short distances...