运动工件 (MA) 在静止时测量动脉脉冲信号:在每个和非平和MA合基线中的时间变化的振幅
M D Mahfuzur Rahman1, Mamun Hasan1, Zhili Hao1
1Department of Mechanical and Aerospace Engineering, Old Dominion University, Norfolk, VA 23529, USA.
Biosensors
|September 26, 2025
概括
动脉脉冲信号中的运动工件 (MA) 不仅仅是基线漂移 (BD). 新的研究表明,时间变化的系统参数 (TVSP) 也会影响脉冲信号波,影响精度.
科学领域:
- 生物医学工程 生物医学工程
- 信号处理 信号处理
- 生理监测 生理监测
背景情况:
- 运动工件 (MA) 引入了测量动脉脉冲信号的显著变化.
- 仅仅将MA视为基线漂移 (BD) 不够用于准确的信号分析.
研究的目的:
- 在动脉脉冲信号中开发MA的分析模型.
- 用触觉传感器研究低频MA (<0.7Hz) 对测量脉冲信号的影响.
主要方法:
- 开发了组织接触传感器 (TCS) 堆作为1DOF系统的分析模型.
- 量化MA作为基线漂移 (BD) 和时间变化的系统参数 (TVSP).
- 利用时间频率分析 (TFA) 来分析测量的脉冲信号.
主要成果:
- 分析模型显示,TVSP导致测量脉冲信号中的时间变化的波.
- TFA验证了TVSP的存在及其对信号波的影响.
- 识别了非平面波-MA合基线作为TVSP的影响.
结论:
- 动脉脉冲信号中的MA包括BD和TVSP.
- TVSP显著影响测量信号的和声内容和基线特征.
- 精确的动脉脉冲信号分析需要考虑MA的BD和TVSP组件.
相关概念视频
Pulse
2.0K
When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical...
The pulse serves as a clinical...
2.0K
Pulse rhythm
1.3K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.3K
Characteristics of Simple Harmonic Motion
17.3K
The key characteristic of the simple harmonic motion is that the acceleration of the system and, therefore, the net force are proportional to the displacement and act in the opposite direction to the displacement. Additionally, the period and frequency of a simple harmonic oscillator are independent of its amplitude. For example, diving boards move faster or slower based on their thickness. A stiff, thick diving board has a large force constant, which causes it to have a smaller period, while a...
17.3K
Special considerations while measuring pulse
913
Assessing a patient's pulse is a fundamental skill in healthcare, but certain situations require special attention:
913
Pulse amplitude and quality
3.0K
Pulse amplitude is a crucial indicator of cardiac health because it provides valuable insights into the strength of left ventricular contractions and the overall uniformity of blood circulation within the vasculature. The strength of the pulse is directly related to the force with which the heart contracts and the volume of blood being pumped.
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
3.0K
Simple Harmonic Motion
14.3K
Simple harmonic motion is the name given to oscillatory motion for a system where the net force can be described by Hooke's law. If the net force can be described by Hooke's law and there is no damping (by friction or other non-conservative forces), then a simple harmonic oscillator will oscillate with equal displacement on either side of the equilibrium position. To derive an equation for period and frequency, the equation of motion is used. The period of a simple harmonic oscillator is given...
14.3K