概括
电透析 (ED) 为缩化 (LiCl) 的传统方法提供了一种节能替代方案. 这种创新的两级ED工艺显著降低了LiCl度的能源消耗和成本.
科学领域:
- 化学工程是化学工程的重要组成部分.
- 材料科学 材料科学 材料科学
- 环境科学 环境科学
背景情况:
- 化 (LiCl) 的传统热度方法,如多效应蒸发和机械蒸汽再压缩 (MVR),耗费大量能量,并导致设备腐蚀.
- 电透析 (ED) 由于其高效率,节能,选择性分离能力和缺乏相变要求,因此是一个有前途的替代方案.
研究的目的:
- 开发和优化一种创新的两级电透析 (ED) 工艺,以实现高效的LiCl度.
- 解决传统热度方法在能源消耗和设备腐蚀方面的局限性.
主要方法:
- 进行了系统的小规模和扩大规模的实验,以开发和优化两级ED过程.
- 性能是根据Li+度,排水中的剩余Li+,能源消耗和水迁移来评估的.
主要成果:
- 优化的ED工艺在缩溶液中达到Li+度22.17g/L,在回收稀释溶液中达到21.17g/L.
- 排放水中的剩余Li+减少到1.08g/L,能源消耗为85.22kWh/t LiCl,水迁移为4.21 L/{m2·h}.
- 经济分析显示,与传统蒸发方法相比,每LiCl节省了14.66美元的成本.
结论:
- 两级ED工艺是工业LiCl度的技术和经济可行的解决方案.
- 这种 ED 方法在效率,节能和环境方面比传统的热处理方法具有显著的优势.
相关概念视频
Electrolysis
30.2K
In a galvanic cell, the electrical work is done by a redox system on its surroundings as electrons produced by the spontaneous redox reactions are transferred through an external circuit. Alternatively, an external circuit does work on a redox system by imposing a voltage sufficient to drive an otherwise nonspontaneous reaction in a process known as electrolysis. For instance, recharging a battery involves the use of an external power source to drive the spontaneous (discharge) cell reaction in...
30.2K
Dialysis
1.6K
Dialysis is a diffusion-based purification process that separates analyte molecules from a complex matrix. This is accomplished by allowing molecules in the solution to pass through a semipermeable membrane into a liquid on the other side. The membrane is usually made of cellulose acetate or cellulose nitrate, and the second liquid must be miscible with the solution. Ions (e.g., chloride or sodium) or organic molecules (e.g., glucose) can pass through the membrane pores, which generally have...
1.6K
Extraction: Advanced Methods
1.1K
Metal ions can be separated from one another by complexation with organic ligands–the chelating agent– to form uncharged chelates. Here, the chelating agent must contain hydrophobic groups and behave as a weak acid, losing a proton to bind with the metal. Since most organic ligands used in this process are insoluble or undergo oxidation in the aqueous phase, the chelating agent is initially added to the organic phase and extracted into the aqueous phase. The metal-ligand complex is...
1.1K
Electrodeposition
1.3K
Electrodeposition is a technique used to separate an analyte from interferents by electrochemical processes. Here, the analyte is a metal ion that can be deposited on an electrode immersed in the sample solution. The electrochemical setup consists of an anode and a cathode. When an electric current is applied to the setup, oxidation occurs at the anode. At the cathode, which consists of a large metal surface, metal ions undergo reduction and deposit onto the surface.
Electrodeposition can...
Electrodeposition can...
1.3K
Optimizing Chromatographic Separations
879
Optimizing chromatographic separations is crucial for obtaining clean separations in a minimum amount of time. Optimization is required for several factors, including kinetic effects related to band broadening, plate height, capacity factor, and separation factor.
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
879
Ion-Exchange Chromatography
1.9K
Ion-exchange chromatography, or IEC, is a technique for separating ions based on their affinity for the stationary phase. The stationary phase is a cross-linked polymer resin with covalently attached ionic functional groups. The functional groups can be either positively charged (cation exchangers) or negatively charged (anion exchangers). A cation exchanger consists of a polymeric anion and active cations, while an anion exchanger is a polymeric cation with active anions. The choice of...
1.9K