YOLO-DCRCF:一种用于检测在电网操作环境中佩戴安全头盔和手套的算法
Jinwei Zhao1, Zhi Yang1,2,3, Baogang Li1,2,3
1Department of Electronic and Communication Engineering, North China Electric Power University, Baoding 071003, China.
Journal of imaging
|September 26, 2025
概括
本研究介绍了YOLO-DCRCF,这是一个先进的算法,用于在电网运行中准确检测安全头盔和手套. 新方法改进了现有的技术,用于加强工人安全监测.
科学领域:
- 电气工程 电气工程
- 计算机视觉 计算机视觉
- 职业安全 在职业安全.
背景情况:
- 在电网运行中,安全头盔和手套等个人防护设备 (PPE) 是至关重要的.
- 传统的个人防护设备检测方法往往是不准确的,因为环境挑战,如照明不良,遮蔽,和密集的劳动力.
研究的目的:
- 开发一种新的算法,YOLO-DCRCF,以提高在电网环境中检测安全头盔和手套使用的准确性和可靠性.
- 在复杂的操作环境中解决现有检测方法的局限性.
主要方法:
- 提出了YOLO-DCRCF算法,这是YOLOv11的增强,集成可变形卷积网络版本2 (DCNv2) 以更好的几何转换建模.
- 引入了重新校准特征金字塔 (RCF) 网络,以改善特征交互和多层次信息捕获.
主要成果:
- 在安全头盔佩戴数据集 (SHWD) 上获得了92.7%的50% IoU (mAP50) 的平均平均精度.
- 在安全头盔和手套佩戴数据集 (SHAGWD) 上获得79.6%的mAP50评分.
- 在SHWD上表现1.1%高于基线YOLOv11模型,在SHAGWD上表现2.7%.
结论:
- 在电网环境中,YOLO-DCRCF模型在检测安全头盔和手套方面表现出卓越的性能.
- 拟议的算法符合电网运营的实时安全监控要求,提高了工人的安全.
相关概念视频
Personal Protective Equipment
2.2K
Personal protective equipment (PPE) is unique clothing or equipment worn by an employee to minimize or prevent exposure to infectious agents. PPE creates a barrier between the employee and the infectious materials. PPE must be readily available in the patient care area. PPE includes gloves, gowns and aprons, masks and respirators, goggles, face shields, shoes, and headcovers:
2.2K
Radial System Protection
420
Radial systems employ time-delay overcurrent relays to reduce load interruptions. When a fault occurs, the nearest breaker opens first, while upstream breakers remain closed due to longer delay settings. This approach ensures minimal disruption to the rest of the system.
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
420
Power System Three-Phase Short Circuits
524
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
524
Distributed Loads: Problem Solving
1.1K
Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
1.1K
Fast Decoupled and DC Powerflow
726
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
726
Line Protection with Impedance Relays
438
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
438