潜水中的可穿戴技术:对心率和氧和监测进行审查,以提高安全性和性能
Tae Sung Park1,2, Min-Gyu Kim3, Jong-Hwan Park1,4,5
1Department of Convergence Medical Institute of Technology, Pusan National University Hospital, Busan 49241, Republic of Korea.
Healthcare (Basel, Switzerland)
|September 27, 2025
概括
监测水下心率 (HR) 和氧和 (SpO2) 对于潜水员的安全至关重要. 当前可穿戴技术的挑战阻碍了在动态水生环境中可靠的实时数据收集.
科学领域:
- 生理学 生理学 生理学
- 生物医学工程 生物医学工程
- 潜水医学是一门潜水医学.
背景情况:
- 水下生理监测 (心率,SpO2) 对于潜水安全至关重要.
- 潜水压力 (压力,缺氧,寒冷) 显著影响心血管和氧化水平.
- 现有的可穿戴传感器在水下环境中面临局限性.
研究的目的:
- 审查潜水期间的心血管和氧化反应.
- 探索水下HR和SpO2监测的技术挑战.
- 讨论加强潜水员安全的未来方向.
主要方法:
- 文献综述综合了目前关于潜水生理学的知识.
- 分析水下传感器应用中的技术局限性.
- 探索多传感器平台和预测分析方面的进展.
主要成果:
- 在自由潜水者中观察到显著的HR下降 (>50%) 和SpO2降低 (<50%).
- 作为早期预警水平提出的深度特定的SpO2值.
- 当前的技术面临信号干扰,寒冷效应和耐用性问题.
结论:
- 解决技术差距对于改善水下监测至关重要.
- 多传感器平台和预测分析可以提高潜水员的安全性.
- 改进的监测系统有潜在的临床应用.
相关概念视频
Special considerations while measuring oxygen saturation
898
Assessing respiratory rate concurrently with pulse measurement is fundamental to patient care, providing valuable insights into the patient's respiratory function. The normal breathing rate for an adult usually falls within a normal range of 12 to 20 breaths per minute. Abnormal respiratory rates can signal underlying health conditions or the need for immediate intervention.
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
898
Pulse Oximetry
1.3K
Pulse oximetry, or SpO2, is a non-invasive method for continuously monitoring arterial oxygen saturation (SaO2). This procedure involves attaching a probe or sensor to the patient's fingertip, forehead, earlobe, or nose bridge. The sensor works by detecting changes in oxygen saturation levels through light signals generated by the oximeter and reflected by the pulsing blood under the probe.
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
1.3K
Guidelines For Measuring Vital Signs
2.7K
Following these guidelines can help nurses accurately measure vital signs, assess changes in patient conditions, and provide timely treatment when necessary. Adhering closely to the guidelines ensures the accuracy and reliability of the results.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
Before taking a patient's vital signs, a nurse would consider and assess the patient's comfort level and ensure appropriate equipment is available.
2.7K
Pulse rhythm
1.3K
Pulse rhythm refers to the pattern of pulsations within specific intervals, offering valuable insights into the regularity or irregularity of the heart's beats as observed through the pattern of pulsation within specific intervals. A regular pulse exhibits a consistent heart rate with uniform waveforms and pulsation force, variations of which can be classified as normal, weak, or bounding.
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
1.3K
Equipments Used To Measure Blood Pressure
3.1K
Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
3.1K
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
1.9K
Oxygen therapy is a pivotal aspect of medical care, particularly for patients with respiratory ailments. Two prominent oxygen-delivering systems include the Venturi mask and the transtracheal oxygen catheter.
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
1.9K


