基于声辐射的腐蚀成像作为一种可能的方法,用于识别结构局部大气腐蚀
Thomas Erlinger1, Christoph Kralovec1, Martin Schagerl1
1Institute of Structural Lightweight Design, Johannes Kepler University Linz, Altenberger Str. 69, Linz, 4040, Upper Austria, Austria.
Ultrasonics
|September 27, 2025
概括
这项研究证明了声辐射 (AE) 成像用于在合金中完全识别腐蚀. 基于AE的腐蚀成像可以定位,量化和描述大气腐蚀,增强结构健康监测.
科学领域:
- 材料科学 材料科学 材料科学
- 机械工程 机械工程
- 非破坏性测试 不破坏性测试
背景情况:
- 合金的大气腐蚀对航空业等行业的结构完整性构成风险.
- 结构健康监测 (SHM) 对于保持结构安全至关重要.
- 声波发射 (AE) 是一种有前途的SHM技术,用于损害定位和范围估计.
研究的目的:
- 研究AE在薄壁结构中局部化,量化和表征大气腐蚀的潜力.
- 开发和评估基于AE的腐蚀成像,以完全识别腐蚀.
- 应对局部化和量化来自大气腐蚀的低振幅AE事件的挑战.
主要方法:
- 利用基于AE的腐蚀成像,结合了许多个AE事件的精确AE源定位.
- 与腐蚀的时间演变相关联的AE数据以描述腐蚀类型.
- 在大气腐蚀条件下将该方法应用于薄壁结构.
主要成果:
- 基于AE的腐蚀成像成功地局部化了腐蚀.
- 该技术有助于估计腐蚀的空间范围.
- AE成像显示了通过分析时间图像演变来表征不同腐蚀类型的潜力.
结论:
- 基于AE的腐蚀成像显示了在结构中完全识别腐蚀的高潜力.
- 这种技术可以显著提升未来的SHM应用在腐蚀监测.
- 该研究验证了AE作为全面腐蚀评估的强大工具.
相关概念视频
Atomic Emission Spectroscopy: Lab
527
AES is a powerful analytical technique, especially effective when used with plasma sources, producing abundant spectra in characteristic emission lines. The Inductively Coupled Plasma (ICP), in particular, yields superior quantitative analytical data due to its high stability, low noise, low background, and minimal interferences under optimal experimental conditions. However, newer air-operated microwave sources are emerging as promising alternatives that could be more cost-effective than...
527
Corrosion of Reinforcement
465
The corrosion of steel reinforcement within concrete is a process influenced by the material's inherent properties and external factors. The high pH level of around 13, provided by calcium hydroxide present in concrete, initially protects the steel reinforcement by promoting the formation of a passive iron oxide layer on its surface.
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
However, over time and under certain conditions like carbonation, chloride ingress, and cracking this protective state can be compromised. Steel has areas with...
465
Atomic Emission Spectroscopy: Overview
3.4K
Atomic emission spectroscopy (AES) is an analytical technique used to determine the elemental composition of a sample by analyzing the light emitted from excited atoms. In AES, atoms in a sample are excited to higher energy levels by thermal energy from high-temperature sources, such as plasma, arcs, or sparks. When these excited atoms return to lower energy states, they emit light at specific wavelengths characteristic of each element. The resulting atomic emission spectrum, which consists of...
3.4K
Atomic Emission Spectroscopy: Instrumentation
1.1K
The instrumentation of atomic emission spectrometry (AES) involves various components, including atomization devices that convert samples into gas-phase atoms and ions. There are two main types of atomization devices: continuous and discrete atomizers. Continuous atomizers, like plasmas and flames, introduce samples in a constant stream, while discrete atomizers inject individual samples using syringes or autosamplers. The most common discrete atomizer is the electrothermal atomizer.
1.1K
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
606
Inductively coupled plasma (ICP) is the common plasma source used in atomic emission spectroscopy (AES), a technique that detects and analyzes various elements in a sample. This method is often called inductively coupled plasma atomic emission spectroscopy (ICP-AES).
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....
606
Atomic Emission Spectroscopy: Interference
570
In atomic emission spectroscopy (AES), high-temperature atomizers excite a broad range of elements and molecules that generate complex emissions from sources such as oxides, hydroxides, and flame combustion products in the flame or plasma. Several strategies can be employed to minimize spectral interferences caused by overlapping emission lines or bands. These include increasing instrument resolution, choosing alternative emission lines, optimally placing the detector in low-background regions,...
570