概括
了解能源行业的人为因素是防止事故的关键. 本研究确定了特定的安全文化和安全气候项目,这些项目有助于解决工作场所安全问题,帮助减少事故的努力.
科学领域:
- 职业健康和安全问题 职业健康和安全问题
- 工业心理学 工业心理学
- 能源部门管理 能源部门管理
背景情况:
- 人类因素对能源行业的事故率有很大影响.
- 糟糕的安全气候和安全文化是关键的根本问题.
- 有效的事故减轻需要了解这些促成因素.
研究的目的:
- 确定影响安全的安全文化和安全气候的特定元素.
- 量化这些因素对公用事业部门安全问题的贡献.
- 为改善安全管理提供可操作的见解.
主要方法:
- 一项问卷调查评估了8个安全文化项目和57个安全气候项目.
- 用于数据分析的结构方程建模 (SEM).
- 使用已建立的合适指数验证SEM模型.
主要成果:
- 发现4个安全文化项目和26个安全气候项目有助于安全问题.
- 该研究确定了贡献因素的具体权重.
- 确定了需要管理和政策关注的关键领域.
结论:
- 安全文化和气候的特定方面与安全问题直接相关.
- 针对特定项目的有针对性的干预措施可以减少事故.
- 调查结果支持基于证据的战略,以提高能源部门的安全性.
相关概念视频
Insulation Coordination
552
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
552
Design Consideration
545
Designing a structure involves a series of considerations, primarily the material's ultimate strength, calculated through tests that measure changes under increased force until the material reaches its breaking point or limit. The ultimate load, where the material breaks, is divided by its original cross-sectional area, resulting in the ultimate normal stress or strength. The ultimate shearing stress is another significant factor taken into account.
The factor of safety is another key...
The factor of safety is another key...
545
Zones of Protection
760
In power systems, the entire setup is divided into protective zones to isolate faults and protect the rest of the network. These zones include generators, transformers, buses, transmission lines, distribution lines, and motors. Each zone can be visualized as a separate room in a house, with each room protected by its own circuit breaker.
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
Protective zones are defined by closed dashed lines, containing one or more components. A key characteristic of these zones is the strategic placement of...
760
Primary Distribution
530
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
530
Household Wiring And Electrical Safety
1.6K
Companies that supply power to most modern households use three conductors, typically called a three-wire line. While one is neutral, the other two are both at 120 V but with opposite polarity, giving a voltage of 240 V between them. With a three-wire line, high-power appliances that require 240 V, such as electric stoves and clothes dryers, are linked between the two hot lines. 120 V appliances can be connected between the neutral and either of the hot lines. The neutral side, which is always...
1.6K
Power Distribution in Three-phase and Single Phase Circuits
602
Power distribution within electrical circuits is a foundational aspect of residential and industrial energy systems. While single-phase power is common in residential settings, three-phase power is the standard for industrial environments with heavy machinery. Each system is different and has advantages, and it's crucial to understand the underlying principles of power distribution and material efficiency.
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...