:

Jingbo Wang1, Harshal D Kaushik1, Roshni Anna Jacob1,2

  • 1Department of Mechanical Engineering, The University of Texas at Dallas, Richardson, TX 75080, USA.

iScience
|October 7, 2025
PubMed
概括

本研究引入了一个三阶段框架,通过预测需求,确定最佳位置和评估电网影响来优化电动汽车 (EV) 充电器部署. 该方法确保了具有成本效益的,可访问的收费,同时保持了电网可靠性.

相关概念视频

Maximum Power Flow and Line Loadability01:23

Maximum Power Flow and Line Loadability

The maximum power flow for lossy transmission lines is derived using ABCD parameters in phasor form. These parameters create a matrix relationship between the sending-end and receiving-end voltages and currents, allowing the determination of the receiving-end current. This relationship facilitates calculating the complex power delivered to the receiving end, from which real and reactive power components are derived.
589
Fast Decoupled and DC Powerflow01:24

Fast Decoupled and DC Powerflow

The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
726
Continuous Charge Distributions01:17

Continuous Charge Distributions

Imagine a bucket of water. It contains many molecules, of the order of 1026 molecules. Thus, although it contains discrete elements (molecules) at the microscopic level, macroscopically, it can be considered continuous. Small volume elements of water, infinitesimal compared to the bulk of the bucket's volume, still contain many molecules. Under this framework, quantized matter is approximated as continuous for practical purposes.
The electric charge can also be subjected to an analogical...
7.9K
The Power Flow Problem and Solution01:26

The Power Flow Problem and Solution

Power flow problem analysis is fundamental for determining real and reactive power flows in network components, such as transmission lines, transformers, and loads. The power system's single-line diagram provides data on the bus, transmission line, and transformer. Each bus k in the system is characterized by four key variables: voltage magnitude Vk​, phase angle δk​, real power Pk​, and reactive power Qk​. Two of these four variables are inputs, while the power flow program computes...
836
Distributed Loads: Problem Solving01:21

Distributed Loads: Problem Solving

Beams are structural elements commonly employed in engineering applications requiring different load-carrying capacities. The first step in analyzing a beam under a distributed load is to simplify the problem by dividing the load into smaller regions, which allows one to consider each region separately and calculate the magnitude of the equivalent resultant load acting on each portion of the beam. The magnitude of the equivalent resultant load for each region can be determined by calculating...
1.1K
Induced Electric Fields: Applications01:27

Induced Electric Fields: Applications

An important distinction exists between the electric field induced by a changing magnetic field and the electrostatic field produced by a fixed charge distribution. Specifically, the induced electric field is nonconservative because it does not work in moving a charge over a closed path. In contrast, the electrostatic field is conservative and does no net work over a closed path. Hence, electric potential can be associated with the electrostatic field but not the induced field. The following...
2.5K