在钻井喷气道建设中的通风管道的安装和维护技术方面的研究进展
Hongbo Zhao1, Xu Wang2, Benguo He1
1State Key Laboratory of Intelligent Deep Metal Mining and Equipment, Northeastern University, Shenyang, 110819, China.
Scientific reports
|October 7, 2025
概括
在钻井和喷气道中的通风系统性能由于空气泄漏和管道阻力而降低. 改进的安装和维护技术对于工人的安全和效率至关重要.
科学领域:
- 土木工程 土木工程是指土木工程.
- 道技术 道技术
- 职业安全 在职业安全.
背景情况:
- 在中国的运输道建设中,钻井和喷气方法普遍存在 (>90%).
- 道通风系统对于施工期间的空气交换和工人安全至关重要.
- 不适当的安装和维护导致通风性能不足于最佳.
研究的目的:
- 审查有关道施工通风系统的安装和维护技术的现有文献.
- 确定导致通风性能下降的因素,特别是空气泄漏和阻力增加.
- 为维护人员提供参考资料,以提高通风系统的有效性.
主要方法:
- 文献综述侧重于道通风管道的安装和维护技术.
- 分析通风管和风扇之间的连接技术.
- 检查主要道内的管道和通过施工车的悬挂技术.
主要成果:
- 空气泄漏和通风管中的空气阻力增加是性能降低的主要原因.
- 管道风扇连接,悬挂和穿过设备的影响系统效率的特定技术.
- 当前的做法往往忽视了正确的安装和维护,导致性能不足.
结论:
- 优化通风管的安装和维护对于实现设计通风性能至关重要.
- 通过改进技术解决空气泄漏和阻力问题,可以提高工人安全和建筑效率.
- 本综述为改善道施工通风系统的维护提供了实际参考.
相关概念视频
Quarrying of Stone
532
Quarrying is the process of extracting stone from a quarry, where specialized techniques are employed to remove large blocks of stone safely and efficiently. This process can involve controlled explosions or more precision-oriented methods such as cutting and drilling.
One common method involves using a diamond belt saw to cut large blocks from the quarry face. These blocks can be about 50 feet long and 12 feet high. After the initial vertical cut, drilling is performed at the base of the...
One common method involves using a diamond belt saw to cut large blocks from the quarry face. These blocks can be about 50 feet long and 12 feet high. After the initial vertical cut, drilling is performed at the base of the...
532
Masonry in Cold and Hot Weather Conditions
330
In cold weather, masonry construction requires specific precautions to ensure mortar does not freeze before curing, as this can significantly weaken its strength and watertightness. Mortar temperature should be maintained between 60°F and 80°F to support proper hydration and curing. Below 40°F, mortar water must be heated, but should not exceed 120°F as high temperatures can reduce mortar's compressive and bond strength.
Other key practices include keeping masonry units...
Other key practices include keeping masonry units...
330
Cavity Drainage and Flashings in Masonry walls
417
Typically, a cavity wall consists of two wythes separated by a gap of at least 2 inches, which may contain insulation while still maintaining a minimum clear space of 1 inch to facilitate adequate drainage. Advanced methods like the insertion of a continuous drainage mat can further reduce this space while ensuring effective moisture expulsion.
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
417
Expansion and Contraction in Masonry Walls
1.3K
Masonry walls are subject to slight expansion and contraction due to variations in temperature and moisture. Thermal movement in masonry is relatively straightforward to measure and plan for. On the other hand, moisture movement poses more of a challenge. New clay masonry units typically absorb water and expand over time under normal environmental conditions. Conversely, new concrete masonry units tend to shrink as they lose the excess moisture acquired during their production process.
To...
To...
1.3K
Posttensioned Masonry Walls
454
Post-tensioned masonry walls use high-strength steel rods or flexible tendons to enhance the strength and efficiency of masonry structures. These elements are securely anchored to the foundation and extend vertically either within the cores of the masonry units or between the masonry wythes. The construction process involves building the wall with these tensioning elements in place and allowing the mortar to fully cure.
Following the curing process, the tensioning begins. Steel rods are...
454
Mechanical Ventilation II: Invasive Ventilation
625
Ventilators are essential medical equipment used to aid patients with respiratory difficulties. Their primary function is to assist or replace spontaneous breathing by providing mechanical ventilation. There are two general classes of mechanical ventilators: negative-pressure and positive-pressure ventilators.
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
625


