由于自然灾害造成的不平等的停电情况
Bo Wang1,2, Han Shi3,4, Yueming 'Lucy' Qiu5
1School of Management, Beijing Institute of Technology, Beijing, China.
Nature communications
|October 8, 2025
概括
自然灾害对中国贫困县的停电造成不成比例的影响,其频率和持续时间增加. 预计气候变化将加剧这种差距,需要为脆弱地区提供有针对性的援助.
科学领域:
- 环境科学 环境科学
- 能源系统 能源系统
- 灾害管理 灾害管理
背景情况:
- 能源系统的可靠性越来越受到自然灾害的威胁.
- 对自然灾害对停电造成的不平等影响的实证研究有限.
- 中国的贫困县因收入,基础设施和地理位置而面临独特的脆弱性.
研究的目的:
- 实证地评估自然灾害对中国停电的影响.
- 调查贫困县与非贫困县对贫困县的影响差异.
- 在气候变化情景下预测未来的影响.
主要方法:
- 利用全国高频点级数据集,对中国 (2019-2021) 的停电和自然灾害进行分析.
- 专注分析中国政府确定的贫困县.
- 采用统计分析来比较贫困和非贫困县之间的停电影响.
主要成果:
- 在贫困地区,自然灾害导致停电频率增加5.19%,停电持续时间增加8.96%.
- 非贫困县的频率增加了3.80%,持续时间增加了5.34%.
- 长期预测表明,气候变化将加剧这些差异.
结论:
- 自然灾害对停电的影响分布不均,不成比例地影响脆弱的贫困县.
- 预计气候变化将扩大能源系统弹性差距.
- 针对性气候基金和防灾战略对脆弱地区至关重要.
相关概念视频
Power System Three-Phase Short Circuits
523
Determining the subtransient fault current in a power system involves representing transformers by their leakage reactances, transmission lines by their equivalent series reactances, and synchronous machines as constant voltage sources behind their subtransient reactances. In this analysis, certain elements are excluded, such as winding resistances, series resistances, shunt admittances, delta-Y phase shifts, armature resistance, saturation, saliency, non-rotating impedance loads, and small...
523
Distribution Reliability and Automation
497
Distribution reliability in electrical power systems is critical for ensuring an uninterrupted power supply to consumers at minimal cost. According to IEEE Standard Terms, reliability is the probability that a device will function without failure over a specified time period or amount of usage. For electric power distribution, this translates to maintaining continuous power supply and addressing customer concerns over power outages. Several indices, as defined by IEEE Standard 1366-2012, are...
497
Primary Distribution
529
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
529
Lossy Lines and Overvoltages
350
Transmission-line series resistance and shunt conductance cause three primary effects: attenuation, distortion, and power losses.
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
Attenuation
When constant series resistance and shunt conductance are present, voltage and current equations are modified. The propagation constant indicates that voltage and current waves consist of both forward and backward traveling components. These waves attenuate as they propagate, with the attenuation factor related to the resistance and conductance. In a...
350
Power Distribution in Three-phase and Single Phase Circuits
599
Power distribution within electrical circuits is a foundational aspect of residential and industrial energy systems. While single-phase power is common in residential settings, three-phase power is the standard for industrial environments with heavy machinery. Each system is different and has advantages, and it's crucial to understand the underlying principles of power distribution and material efficiency.
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...
Single-Phase Power Distribution:
Single-phase circuits are typical in household settings;...
599
Line Protection with Impedance Relays
432
Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
Under normal conditions, low load currents keep the measured...
432