区域协调可以减轻低碳电力系统的成本负担
Jacob Wessel1, Afm Kamal Chowdhury2, Thomas Wild2,3
1Department of Civil and Environmental Engineering, Tufts University, Medford, MA, USA. jwesse03@tufts.edu.
Nature communications
|October 10, 2025
概括
南美洲的区域电力协调可以以更低的成本实现低碳能源系统. 国际合作显著降低了开支,使得脱碳变得可行,尽管可再生能源投资存在不确定性.
科学领域:
- 能源系统分析 能源系统分析
- 气候变化缓解缓解 气候变化缓解
- 整合可再生能源的整合
背景情况:
- 全球南方低碳电力系统的长期规划在基础设施投资方面面临重大不确定性.
- 国家电网经常独立运行,尽管区域一体化可能带来好处.
研究的目的:
- 检查南美子区域区域区域电力协调的价值.
- 在严格的排放目标和技术经济不确定性下,评估协调对脱碳成本的影响.
主要方法:
- 模拟一个具有可变可再生资源的南美次区域.
- 通过一系列技术经济假设和减排目标进行分析.
主要成果:
- 脱碳是可以通过适度的成本溢价实现的,通过国际协调进一步降低.
- 区域协调在不同情景中弥补了可再生能源部署的差异.
- 国家脱碳途径对技术选择敏感,如果没有协调,成本会大幅增加 (147亿至228亿美元,而35亿至70亿美元).
结论:
- 区域电力协调为实现南美洲的低碳能源系统提供了可观的成本节约.
- 国际合作是降低成本和提高脱碳可行性的关键.
- 这些发现适用于通过加强国际合作实现排放目标的其他地区.
相关概念视频
Load-frequency control
583
Load-frequency control (LFC) is vital for maintaining power system stability, ensuring that frequency and power flows remain within acceptable limits during load changes. Turbine-governor control eliminates rotor accelerations and decelerations following load changes. However, a steady-state frequency error persists when the change in the turbine-governor reference setting is zero. In an interconnected power system, each area agrees to export or import a scheduled amount of power through...
583
Secondary Distribution
520
Secondary distribution systems provide electrical energy at the utilization voltage levels from distribution transformers to customer meters. Typical secondary voltages in the United States include 120/240 V for residential use, 208Y/120 V for residential and commercial use, and 480Y/277 V for industrial and high-rise commercial use.
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
In residential areas, 120/240 V single-phase, three-wire service is commonly used for lighting, outlets, and large appliances. Urban areas with high-density loads...
520
Insulation Coordination
534
Insulation coordination is the process of matching electric equipment's insulation strength with protective device characteristics to protect the equipment against expected overvoltages. This selection is based on engineering judgment and cost. Equipment can generally withstand short-duration high transient overvoltages, but repeated tests with identical waveforms can yield inconsistent results. As a result, standard impulse voltage waveforms are used for testing, defined by specific times...
534
Power System Distribution
999
Power system distribution involves delivering electrical energy from power plants to consumers through a network of transmission and distribution systems. The process begins at power plants, where energy from coal, gas, nuclear, water, and wind is converted into electrical energy. These plants use three-phase generators, typically rated between 50 to 1300 MVA, with terminal voltages ranging from a few kV to 20 kV, depending on the size and age of the units.
The transmission system is designed...
The transmission system is designed...
999
Primary Distribution
504
Primary distribution systems deliver electrical power from substations to consumers through various voltage classes, with 15-kV class voltages being predominant among U.S. utilities. Older 2.5- and 5-kV classes are being replaced by 15-kV primaries, while higher 25- to 34.5-kV classes are used in high-density urban areas and rural regions with long feeders. Three-phase, four-wire multigrounded systems are widely employed for balanced power delivery, using the neutral wire as a grounding point.
504
Fast Decoupled and DC Powerflow
703
The fast decoupled power flow method addresses contingencies in power system operations, such as generator outages or transmission line failures. This method provides quick power flow solutions, essential for real-time system adjustments. Fast decoupled power flow algorithms simplify the Jacobian matrix by neglecting certain elements, leading to two sets of decoupled equations:
703